|
IEC61970 17v07
|
|
- w -
- w
: IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST2
- waterStartingTime
: IEC61970::Base::Generation::GenerationTrainingSimulation::HydroTurbine
- waterTunnelSurgeChamberSimulation
: IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroFrancis
, IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroPelton
- wdtd
: IEC61970::Dynamics::StandardModels::WindDynamics::WindContPType3IEC
- wfmax
: IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU
- wfmin
: IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU
- wfnl
: IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovCT1
, IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovCT2
- wfspd
: IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovCT1
, IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovCT2
- WindContCurrLimIEC
: IEC61970::Dynamics::StandardModels::WindDynamics::WindDynamicsLookupTable
- WindContPType3IEC
: IEC61970::Dynamics::StandardModels::WindDynamics::WindDynamicsLookupTable
- WindContRotorRIEC
: IEC61970::Dynamics::StandardModels::WindDynamics::WindDynamicsLookupTable
- WindGenTurbineType1IEC
: IEC61970::Dynamics::StandardModels::WindDynamics::WindAeroConstIEC
- WindGenTurbineType2IEC
: IEC61970::Dynamics::StandardModels::WindDynamics::WindContRotorRIEC
, IEC61970::Dynamics::StandardModels::WindDynamics::WindPitchContEmulIEC
- WindGenTurbineType3IEC
: IEC61970::Dynamics::StandardModels::WindDynamics::WindAeroLinearIEC
, IEC61970::Dynamics::StandardModels::WindDynamics::WindContPitchAngleIEC
, IEC61970::Dynamics::StandardModels::WindDynamics::WindContPType3IEC
, IEC61970::Dynamics::StandardModels::WindDynamics::WindMechIEC
- windGenUnitType
: IEC61970::Base::Generation::Production::WindGeneratingUnit
- windingConnectionAngle
: IEC61970::Base::Wires::PhaseTapChangerAsymmetrical
- windLVRTQcontrolModesType
: IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC
- WindPlantFreqPcontrolIEC
: IEC61970::Dynamics::StandardModels::WindDynamics::WindDynamicsLookupTable
- WindPlantIEC
: IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantFreqPcontrolIEC
- WindPlantReactiveControlIEC
: IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantIEC
- windQcontrolModesType
: IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC
- WindTurbineType1or2IEC
: IEC61970::Dynamics::StandardModels::WindDynamics::WindMechIEC
, IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC
- WindTurbineType3or4Dynamics
: IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantDynamics
- WindTurbineType3or4IEC
: IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC
, IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC
, IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC
- WindTurbineType4aIEC
: IEC61970::Dynamics::StandardModels::WindDynamics::WindContPType4aIEC
- WindTurbineType4bIEC
: IEC61970::Dynamics::StandardModels::WindDynamics::WindContPType4bIEC
, IEC61970::Dynamics::StandardModels::WindDynamics::WindMechIEC
- wmax1
: IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU
- wmax2
: IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU
- wwmax
: IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU
- wwmin
: IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU