#include <WindContPitchAngleIEC.h>
Public Attributes | |
IEC61970::Base::Domain::Float | dthetamax |
IEC61970::Base::Domain::Float | dthetamin |
IEC61970::Base::Domain::PU | kic |
IEC61970::Base::Domain::PU | kiomega |
IEC61970::Base::Domain::PU | kpc |
IEC61970::Base::Domain::PU | kpomega |
IEC61970::Base::Domain::PU | kpx |
IEC61970::Base::Domain::AngleDegrees | thetamax |
IEC61970::Base::Domain::AngleDegrees | thetamin |
IEC61970::Base::Domain::Seconds | ttheta |
IEC61970::Dynamics::StandardModels::WindDynamics::WindGenTurbineType3IEC * | WindGenTurbineType3IEC |
Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject | |
IEC61970::Base::Domain::String | aliasName |
IEC61970::Base::Domain::String | description |
IEC61970::Base::Domain::String | mRID |
IEC61970::Base::Domain::String | name |
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > | DiagramObjects |
Pitch angle control model.
Reference: IEC Standard 61400-27-1 Section 6.6.5.8.
IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::WindDynamics::WindContPitchAngleIEC::dthetamax |
Maximum pitch positive ramp rate (dthetamax). It is type dependent parameter. Unit = degrees/sec.
IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::WindDynamics::WindContPitchAngleIEC::dthetamin |
Maximum pitch negative ramp rate (dthetamin). It is type dependent parameter. Unit = degrees/sec.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContPitchAngleIEC::kic |
Power PI controller integration gain (KIc). It is type dependent parameter.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContPitchAngleIEC::kiomega |
Speed PI controller integration gain (KIomega). It is type dependent parameter.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContPitchAngleIEC::kpc |
Power PI controller proportional gain (KPc). It is type dependent parameter.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContPitchAngleIEC::kpomega |
Speed PI controller proportional gain (KPomega). It is type dependent parameter.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContPitchAngleIEC::kpx |
Pitch cross coupling gain (KPX). It is type dependent parameter.
IEC61970::Base::Domain::AngleDegrees IEC61970::Dynamics::StandardModels::WindDynamics::WindContPitchAngleIEC::thetamax |
Maximum pitch angle (thetamax). It is type dependent parameter.
IEC61970::Base::Domain::AngleDegrees IEC61970::Dynamics::StandardModels::WindDynamics::WindContPitchAngleIEC::thetamin |
Minimum pitch angle (thetamin). It is type dependent parameter.
IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindContPitchAngleIEC::ttheta |
Pitch time constant (ttheta). It is type dependent parameter.
IEC61970::Dynamics::StandardModels::WindDynamics::WindGenTurbineType3IEC* IEC61970::Dynamics::StandardModels::WindDynamics::WindContPitchAngleIEC::WindGenTurbineType3IEC |
Wind turbine type 3 model with which this pitch control model is associated.