#include <WindPlantFreqPcontrolIEC.h>
Public Attributes | |
IEC61970::Base::Domain::PU | dprefmax |
IEC61970::Base::Domain::PU | dprefmin |
IEC61970::Base::Domain::Float | kiwpp |
IEC61970::Base::Domain::Float | kpwpp |
IEC61970::Base::Domain::PU | prefmax |
IEC61970::Base::Domain::PU | prefmin |
IEC61970::Base::Domain::Seconds | tpft |
IEC61970::Base::Domain::Seconds | tpfv |
IEC61970::Base::Domain::Seconds | twpffilt |
IEC61970::Base::Domain::Seconds | twppfilt |
IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantIEC * | WindPlantIEC |
Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject | |
IEC61970::Base::Domain::String | aliasName |
IEC61970::Base::Domain::String | description |
IEC61970::Base::Domain::String | mRID |
IEC61970::Base::Domain::String | name |
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > | DiagramObjects |
Frequency and active power controller model.
Reference: IEC Standard 61400-27-1 Annex E.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantFreqPcontrolIEC::dprefmax |
Maximum ramp rate of pWTref request from the plant controller to the wind turbines (dprefmax). It is project dependent parameter.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantFreqPcontrolIEC::dprefmin |
Minimum (negative) ramp rate of pWTref request from the plant controller to the wind turbines (dprefmin). It is project dependent parameter.
IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantFreqPcontrolIEC::kiwpp |
Plant P controller integral gain (KIWPp). It is type dependent parameter.
IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantFreqPcontrolIEC::kpwpp |
Plant P controller proportional gain (KPWPp). It is type dependent parameter.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantFreqPcontrolIEC::prefmax |
Maximum pWTref request from the plant controller to the wind turbines (prefmax). It is type dependent parameter.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantFreqPcontrolIEC::prefmin |
Minimum pWTref request from the plant controller to the wind turbines (prefmin). It is type dependent parameter.
IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantFreqPcontrolIEC::tpft |
Lead time constant in reference value transfer function (Tpft). It is type dependent parameter.
IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantFreqPcontrolIEC::tpfv |
Lag time constant in reference value transfer function (Tpfv). It is type dependent parameter.
IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantFreqPcontrolIEC::twpffilt |
Filter time constant for frequency measurement (TWPffilt). It is type dependent parameter.
IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantFreqPcontrolIEC::twppfilt |
Filter time constant for active power measurement (TWPpfilt). It is type dependent parameter.
IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantIEC* IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantFreqPcontrolIEC::WindPlantIEC |
Wind plant model with which this wind plant frequency and active power control is associated.