IEC61970 17v07
Public Attributes | List of all members
IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC Class Reference

#include <WindContCurrLimIEC.h>

Inheritance diagram for IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::PU imax
 
IEC61970::Base::Domain::PU imaxdip
 
IEC61970::Base::Domain::Boolean mdfslim
 
IEC61970::Base::Domain::Boolean mqpri
 
IEC61970::Base::Domain::Seconds tufilt
 
IEC61970::Dynamics::StandardModels::WindDynamics::WindTurbineType3or4IECWindTurbineType3or4IEC
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

Current limitation model. The current limitation model combines the physical limits.

Reference: IEC Standard 61400-27-1 Section 6.6.5.7.

Member Data Documentation

◆ imax

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC::imax

Maximum continuous current at the wind turbine terminals (imax). It is type dependent parameter.

◆ imaxdip

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC::imaxdip

Maximum current during voltage dip at the wind turbine terminals (imax,dip). It is project dependent parameter.

◆ mdfslim

IEC61970::Base::Domain::Boolean IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC::mdfslim

Limitation of type 3 stator current (MDFSLim):

  • false=0: total current limitation,
  • true=1: stator current limitation).

It is type dependent parameter.

◆ mqpri

IEC61970::Base::Domain::Boolean IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC::mqpri

Prioritisation of q control during LVRT (Mqpri):

  • true = 1: reactive power priority,
  • false = 0: active power priority.

It is project dependent parameter.

◆ tufilt

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC::tufilt

Voltage measurement filter time constant (Tufilt). It is type dependent parameter.

◆ WindTurbineType3or4IEC

IEC61970::Dynamics::StandardModels::WindDynamics::WindTurbineType3or4IEC* IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC::WindTurbineType3or4IEC

Wind turbine type 3 or 4 model with which this wind control current limitation model is associated.


The documentation for this class was generated from the following files: