#include <WindContCurrLimIEC.h>
Public Attributes | |
IEC61970::Base::Domain::PU | imax |
IEC61970::Base::Domain::PU | imaxdip |
IEC61970::Base::Domain::Boolean | mdfslim |
IEC61970::Base::Domain::Boolean | mqpri |
IEC61970::Base::Domain::Seconds | tufilt |
IEC61970::Dynamics::StandardModels::WindDynamics::WindTurbineType3or4IEC * | WindTurbineType3or4IEC |
Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject | |
IEC61970::Base::Domain::String | aliasName |
IEC61970::Base::Domain::String | description |
IEC61970::Base::Domain::String | mRID |
IEC61970::Base::Domain::String | name |
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > | DiagramObjects |
Current limitation model. The current limitation model combines the physical limits.
Reference: IEC Standard 61400-27-1 Section 6.6.5.7.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC::imax |
Maximum continuous current at the wind turbine terminals (imax). It is type dependent parameter.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC::imaxdip |
Maximum current during voltage dip at the wind turbine terminals (imax,dip). It is project dependent parameter.
IEC61970::Base::Domain::Boolean IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC::mdfslim |
Limitation of type 3 stator current (MDFSLim):
It is type dependent parameter.
IEC61970::Base::Domain::Boolean IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC::mqpri |
Prioritisation of q control during LVRT (Mqpri):
It is project dependent parameter.
IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC::tufilt |
Voltage measurement filter time constant (Tufilt). It is type dependent parameter.
IEC61970::Dynamics::StandardModels::WindDynamics::WindTurbineType3or4IEC* IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC::WindTurbineType3or4IEC |
Wind turbine type 3 or 4 model with which this wind control current limitation model is associated.