#include <WindProtectionIEC.h>
Public Attributes | |
IEC61970::Base::Domain::PU | fover |
IEC61970::Base::Domain::PU | funder |
IEC61970::Base::Domain::Seconds | tfover |
IEC61970::Base::Domain::Seconds | tfunder |
IEC61970::Base::Domain::Seconds | tuover |
IEC61970::Base::Domain::Seconds | tuunder |
IEC61970::Base::Domain::PU | uover |
IEC61970::Base::Domain::PU | uunder |
IEC61970::Dynamics::StandardModels::WindDynamics::WindTurbineType3or4IEC * | WindTurbineType3or4IEC |
IEC61970::Dynamics::StandardModels::WindDynamics::WindTurbineType1or2IEC * | WindTurbineType1or2IEC |
Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject | |
IEC61970::Base::Domain::String | aliasName |
IEC61970::Base::Domain::String | description |
IEC61970::Base::Domain::String | mRID |
IEC61970::Base::Domain::String | name |
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > | DiagramObjects |
The grid protection model includes protection against over and under voltage, and against over and under frequency.
Reference: IEC Standard 614000-27-1 Section 6.6.6.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::fover |
Set of wind turbine over frequency protection levels (fover). It is project dependent parameter.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::funder |
Set of wind turbine under frequency protection levels (funder). It is project dependent parameter.
IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::tfover |
Set of corresponding wind turbine over frequency protection disconnection times (Tfover). It is project dependent parameter.
IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::tfunder |
Set of corresponding wind turbine under frequency protection disconnection times (Tfunder). It is project dependent parameter.
IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::tuover |
Set of corresponding wind turbine over voltage protection disconnection times (Tuover). It is project dependent parameter.
IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::tuunder |
Set of corresponding wind turbine under voltage protection disconnection times (Tuunder). It is project dependent parameter.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::uover |
Set of wind turbine over voltage protection levels (uover). It is project dependent parameter.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::uunder |
Set of wind turbine under voltage protection levels (uunder). It is project dependent parameter.
IEC61970::Dynamics::StandardModels::WindDynamics::WindTurbineType1or2IEC* IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::WindTurbineType1or2IEC |
Wind generator type 1 or 2 model with which this wind turbine protection model is associated.
IEC61970::Dynamics::StandardModels::WindDynamics::WindTurbineType3or4IEC* IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::WindTurbineType3or4IEC |
Wind generator type 3 or 4 model with which this wind turbine protection model is associated.