IEC61970 17v07
Public Attributes | List of all members
IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC Class Reference

#include <WindContQIEC.h>

Inheritance diagram for IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::PU iqh1
 
IEC61970::Base::Domain::PU iqmax
 
IEC61970::Base::Domain::PU iqmin
 
IEC61970::Base::Domain::PU iqpost
 
IEC61970::Base::Domain::PU kiq
 
IEC61970::Base::Domain::PU kiu
 
IEC61970::Base::Domain::PU kpq
 
IEC61970::Base::Domain::PU kpu
 
IEC61970::Base::Domain::PU kqv
 
IEC61970::Base::Domain::PU qmax
 
IEC61970::Base::Domain::PU qmin
 
IEC61970::Base::Domain::PU rdroop
 
IEC61970::Base::Domain::Seconds tiq
 
IEC61970::Base::Domain::Seconds tpfilt
 
IEC61970::Base::Domain::Seconds tpost
 
IEC61970::Base::Domain::Seconds tqord
 
IEC61970::Base::Domain::Seconds tufilt
 
IEC61970::Base::Domain::PU udb1
 
IEC61970::Base::Domain::PU udb2
 
IEC61970::Base::Domain::PU umax
 
IEC61970::Base::Domain::PU umin
 
IEC61970::Base::Domain::PU uqdip
 
IEC61970::Base::Domain::PU uref0
 
IEC61970::Dynamics::StandardModels::WindDynamics::WindLVRTQcontrolModesKind windLVRTQcontrolModesType = IEC61970::Dynamics::StandardModels::WindDynamics::WindLVRTQcontrolModesKind::_undef
 
IEC61970::Dynamics::StandardModels::WindDynamics::WindQcontrolModesKind windQcontrolModesType = IEC61970::Dynamics::StandardModels::WindDynamics::WindQcontrolModesKind::_undef
 
IEC61970::Base::Domain::PU xdroop
 
IEC61970::Dynamics::StandardModels::WindDynamics::WindTurbineType3or4IECWindTurbineType3or4IEC
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

Q control model.

Reference: IEC Standard 61400-27-1 Section 6.6.5.6.

Member Data Documentation

◆ iqh1

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::iqh1

Maximum reactive current injection during dip (iqh1). It is type dependent parameter.

◆ iqmax

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::iqmax

Maximum reactive current injection (iqmax). It is type dependent parameter.

◆ iqmin

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::iqmin

Minimum reactive current injection (iqmin). It is type dependent parameter.

◆ iqpost

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::iqpost

Post fault reactive current injection (iqpost). It is project dependent parameter.

◆ kiq

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::kiq

Reactive power PI controller integration gain (KI,q). It is type dependent parameter.

◆ kiu

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::kiu

Voltage PI controller integration gain (KI,u). It is type dependent parameter.

◆ kpq

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::kpq

Reactive power PI controller proportional gain (KP,q). It is type dependent parameter.

◆ kpu

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::kpu

Voltage PI controller proportional gain (KP,u). It is type dependent parameter.

◆ kqv

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::kqv

Voltage scaling factor for LVRT current (Kqv). It is project dependent parameter.

◆ qmax

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::qmax

Maximum reactive power (qmax). It is type dependent parameter.

◆ qmin

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::qmin

Minimum reactive power (qmin). It is type dependent parameter.

◆ rdroop

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::rdroop

Resistive component of voltage drop impedance (rdroop). It is project dependent parameter.

◆ tiq

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::tiq

Time constant in reactive current lag (Tiq). It is type dependent parameter.

◆ tpfilt

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::tpfilt

Power measurement filter time constant (Tpfilt). It is type dependent parameter.

◆ tpost

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::tpost

Length of time period where post fault reactive power is injected (Tpost). It is project dependent parameter.

◆ tqord

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::tqord

Time constant in reactive power order lag (Tqord). It is type dependent parameter.

◆ tufilt

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::tufilt

Voltage measurement filter time constant (Tufilt). It is type dependent parameter.

◆ udb1

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::udb1

Voltage dead band lower limit (udb1). It is type dependent parameter.

◆ udb2

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::udb2

Voltage dead band upper limit (udb2). It is type dependent parameter.

◆ umax

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::umax

Maximum voltage in voltage PI controller integral term (umax). It is type dependent parameter.

◆ umin

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::umin

Minimum voltage in voltage PI controller integral term (umin). It is type dependent parameter.

◆ uqdip

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::uqdip

Voltage threshold for LVRT detection in q control (uqdip). It is type dependent parameter.

◆ uref0

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::uref0

User defined bias in voltage reference (uref0), used when MqG = MG,u. It is case dependent parameter.

◆ windLVRTQcontrolModesType

IEC61970::Dynamics::StandardModels::WindDynamics::WindLVRTQcontrolModesKind IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::windLVRTQcontrolModesType = IEC61970::Dynamics::StandardModels::WindDynamics::WindLVRTQcontrolModesKind::_undef

Types of LVRT Q control modes (MqLVRT). It is project dependent parameter.

◆ windQcontrolModesType

IEC61970::Dynamics::StandardModels::WindDynamics::WindQcontrolModesKind IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::windQcontrolModesType = IEC61970::Dynamics::StandardModels::WindDynamics::WindQcontrolModesKind::_undef

Types of general wind turbine Q control modes (MqG). It is project dependent parameter.

◆ WindTurbineType3or4IEC

IEC61970::Dynamics::StandardModels::WindDynamics::WindTurbineType3or4IEC* IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::WindTurbineType3or4IEC

Wind turbine type 3 or 4 model with which this reactive control mode is associated.

◆ xdroop

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC::xdroop

Inductive component of voltage drop impedance (xdroop). It is project dependent parameter.


The documentation for this class was generated from the following files: