#include <IdentifiedObject.h>
Inherits BaseClass.
Inherited by IEC61970::Base::Contingency::Contingency, IEC61970::Base::Contingency::ContingencyElement, IEC61970::Base::ControlArea::AltGeneratingUnitMeas, IEC61970::Base::ControlArea::AltTieMeas, IEC61970::Base::ControlArea::ControlAreaGeneratingUnit, IEC61970::Base::ControlArea::TieFlow, IEC61970::Base::Core::ACDCTerminal, IEC61970::Base::Core::BaseFrequency, IEC61970::Base::Core::BasePower, IEC61970::Base::Core::BaseVoltage, IEC61970::Base::Core::BasicIntervalSchedule, IEC61970::Base::Core::ConnectivityNode, IEC61970::Base::Core::Curve, IEC61970::Base::Core::GeographicalRegion, IEC61970::Base::Core::OperatingParticipant, IEC61970::Base::Core::PowerSystemResource, IEC61970::Base::Core::PSRType, IEC61970::Base::Core::ReportingGroup, IEC61970::Base::Core::ReportingSuperGroup, IEC61970::Base::Core::SubGeographicalRegion, IEC61970::Base::DC::DCNode, IEC61970::Base::DC::DCTopologicalIsland, IEC61970::Base::DC::DCTopologicalNode, IEC61970::Base::DiagramLayout::Diagram, IEC61970::Base::DiagramLayout::DiagramObject, IEC61970::Base::DiagramLayout::DiagramObjectStyle, IEC61970::Base::DiagramLayout::DiagramStyle, IEC61970::Base::DiagramLayout::VisibilityLayer, IEC61970::Base::Faults::Fault, IEC61970::Base::Faults::FaultCauseType, IEC61970::Base::Generation::Production::FossilFuel, IEC61970::Base::Generation::Production::StartupModel, IEC61970::Base::ICCPConfiguration::BilateralExchangeActor, IEC61970::Base::ICCPConfiguration::BilateralExchangeAgreement, IEC61970::Base::ICCPConfiguration::ICCPInformationMessage, IEC61970::Base::ICCPConfiguration::ProvidedBilateralPoint, IEC61970::Base::LoadModel::DayType, IEC61970::Base::LoadModel::EnergyArea, IEC61970::Base::LoadModel::LoadGroup, IEC61970::Base::LoadModel::LoadResponseCharacteristic, IEC61970::Base::LoadModel::Season, IEC61970::Base::Meas::IOPoint, IEC61970::Base::Meas::Limit, IEC61970::Base::Meas::LimitSet, IEC61970::Base::Meas::Measurement, IEC61970::Base::Meas::MeasurementValueSource, IEC61970::Base::Meas::ValueAliasSet, IEC61970::Base::Meas::ValueToAlias, IEC61970::Base::OperationalLimits::BranchGroup, IEC61970::Base::OperationalLimits::OperationalLimit, IEC61970::Base::OperationalLimits::OperationalLimitSet, IEC61970::Base::OperationalLimits::OperationalLimitType, IEC61970::Base::Protection::RecloseSequence, IEC61970::Base::SCADA::RemotePoint, IEC61970::Base::Topology::BusNameMarker, IEC61970::Base::Topology::TopologicalIsland, IEC61970::Base::Topology::TopologicalNode, IEC61970::Base::Wires::MutualCoupling, IEC61970::Base::Wires::PerLengthLineParameter, IEC61970::Base::Wires::PhaseTapChangerTable, IEC61970::Base::Wires::RatioTapChangerTable, IEC61970::Base::Wires::TransformerCoreAdmittance, IEC61970::Base::Wires::TransformerEnd, IEC61970::Base::Wires::TransformerMeshImpedance, IEC61970::Base::Wires::TransformerStarImpedance, IEC61970::Dynamics::StandardInterconnections::RemoteInputSignal, IEC61970::Dynamics::StandardModels::DynamicsFunctionBlock, IEC61970::Dynamics::StandardModels::LoadDynamics::LoadDynamics, IEC61970::Dynamics::StandardModels::LoadDynamics::LoadMotor, IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic, IEC61970::Dynamics::StandardModels::VoltageCompensatorDynamics::GenICompensationForGenJ, IEC61970::Dynamics::StandardModels::WindDynamics::WindAeroConstIEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindAeroOneDimIEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindAeroTwoDimIEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindContCurrLimIEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindContPitchAngleIEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindContPType3IEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindContPType4aIEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindContPType4bIEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindContQIEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindContQLimIEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindContQPQULimIEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindContRotorRIEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindDynamicsLookupTable, IEC61970::Dynamics::StandardModels::WindDynamics::WindGenType3IEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindGenType4IEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindMechIEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindPitchContPowerIEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantFreqPcontrolIEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindPlantReactiveControlIEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC, IEC61970::Dynamics::StandardModels::WindDynamics::WindRefFrameRotIEC, and IEC61970::Part303::GenericDataset::Profile.
Public Attributes | |
IEC61970::Base::Domain::String | aliasName |
IEC61970::Base::Domain::String | description |
IEC61970::Base::Domain::String | mRID |
IEC61970::Base::Domain::String | name |
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > | DiagramObjects |
This is a root class to provide common identification for all classes needing identification and naming attributes.
IEC61970::Base::Domain::String IEC61970::Base::Core::IdentifiedObject::aliasName |
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.
IEC61970::Base::Domain::String IEC61970::Base::Core::IdentifiedObject::description |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
std::list<IEC61970::Base::DiagramLayout::DiagramObject*> IEC61970::Base::Core::IdentifiedObject::DiagramObjects |
The diagram objects that are associated with the domain object.
IEC61970::Base::Domain::String IEC61970::Base::Core::IdentifiedObject::mRID |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
IEC61970::Base::Domain::String IEC61970::Base::Core::IdentifiedObject::name |
The name is any free human readable and possibly non unique text naming the object.