IEC61970 17v23
Public Attributes | List of all members
IEC61970::Dynamics::StandardModels::WindDynamics::WindContRotorRIEC Class Reference

#include <WindContRotorRIEC.h>

Inheritance diagram for IEC61970::Dynamics::StandardModels::WindDynamics::WindContRotorRIEC:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Dynamics::StandardModels::WindDynamics::WindContRotorRIEC:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::PU kirr
 
IEC61970::Base::Domain::Float komegafilt
 
IEC61970::Base::Domain::Float kpfilt
 
IEC61970::Base::Domain::PU kprr
 
IEC61970::Base::Domain::PU rmax
 
IEC61970::Base::Domain::PU rmin
 
IEC61970::Base::Domain::Seconds tomegafiltrr
 
IEC61970::Base::Domain::Seconds tpfiltrr
 
IEC61970::Dynamics::StandardModels::WindDynamics::WindGenTurbineType2IECWindGenTurbineType2IEC
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

Rotor resistance control model.

Reference: IEC Standard 61400-27-1 Section 5.6.5.3.

Member Data Documentation

◆ kirr

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContRotorRIEC::kirr

Integral gain in rotor resistance PI controller (KIrr). It is type dependent parameter.

◆ komegafilt

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::WindDynamics::WindContRotorRIEC::komegafilt

Filter gain for generator speed measurement (Komegafilt). It is type dependent parameter.

◆ kpfilt

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::WindDynamics::WindContRotorRIEC::kpfilt

Filter gain for power measurement (Kpfilt). It is type dependent parameter.

◆ kprr

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContRotorRIEC::kprr

Proportional gain in rotor resistance PI controller (KPrr). It is type dependent parameter.

◆ rmax

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContRotorRIEC::rmax

Maximum rotor resistance (rmax). It is type dependent parameter.

◆ rmin

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContRotorRIEC::rmin

Minimum rotor resistance (rmin). It is type dependent parameter.

◆ tomegafiltrr

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindContRotorRIEC::tomegafiltrr

Filter time constant for generator speed measurement (Tomegafiltrr). It is type dependent parameter.

◆ tpfiltrr

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindContRotorRIEC::tpfiltrr

Filter time constant for power measurement (Tpfiltrr). It is type dependent parameter.

◆ WindGenTurbineType2IEC

IEC61970::Dynamics::StandardModels::WindDynamics::WindGenTurbineType2IEC* IEC61970::Dynamics::StandardModels::WindDynamics::WindContRotorRIEC::WindGenTurbineType2IEC

Wind turbine type 2 model with whitch this wind control rotor resistance model is associated.


The documentation for this class was generated from the following files: