CIM++ Adapted CIM_SINERGIEN Codebase
|
#include <TransformerEnd.h>
Public Attributes | |
IEC61970::Base::Domain::PerCent | bmagSat |
IEC61970::Base::Domain::Integer | endNumber |
IEC61970::Base::Domain::Boolean | grounded |
IEC61970::Base::Domain::Voltage | magBaseU |
IEC61970::Base::Domain::PerCent | magSatFlux |
IEC61970::Base::Domain::Resistance | rground |
IEC61970::Base::Domain::Reactance | xground |
IEC61970::Base::Wires::PhaseTapChanger * | PhaseTapChanger |
IEC61970::Base::Wires::TransformerStarImpedance * | StarImpedance |
IEC61970::Base::Wires::RatioTapChanger * | RatioTapChanger |
IEC61970::Base::Core::BaseVoltage * | BaseVoltage |
IEC61970::Base::Core::Terminal * | Terminal |
Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject | |
IEC61970::Base::Domain::String | aliasName |
IEC61970::Base::Domain::String | description |
IEC61970::Base::Domain::String | mRID |
IEC61970::Base::Domain::String | name |
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > | DiagramObjects |
A conducting connection point of a power transformer. It corresponds to a physical transformer winding terminal. In earlier CIM versions, the TransformerWinding class served a similar purpose, but this class is more flexible because it associates to terminal but is not a specialization of ConductingEquipment.
IEC61970::Base::Core::BaseVoltage* IEC61970::Base::Wires::TransformerEnd::BaseVoltage |
Base voltage of the transformer end. This is essential for PU calculation.
IEC61970::Base::Domain::PerCent IEC61970::Base::Wires::TransformerEnd::bmagSat |
Core shunt magnetizing susceptance in the saturation region.
IEC61970::Base::Domain::Integer IEC61970::Base::Wires::TransformerEnd::endNumber |
Number for this transformer end, corresponding to the end's order in the power transformer vector group or phase angle clock number. Highest voltage winding should be 1. Each end within a power transformer should have a unique subsequent end number. Note the transformer end number need not match the terminal sequence number.
IEC61970::Base::Domain::Boolean IEC61970::Base::Wires::TransformerEnd::grounded |
(for Yn and Zn connections) True if the neutral is solidly grounded.
IEC61970::Base::Domain::Voltage IEC61970::Base::Wires::TransformerEnd::magBaseU |
The reference voltage at which the magnetizing saturation measurements were made
IEC61970::Base::Domain::PerCent IEC61970::Base::Wires::TransformerEnd::magSatFlux |
Core magnetizing saturation curve knee flux level.
IEC61970::Base::Wires::PhaseTapChanger* IEC61970::Base::Wires::TransformerEnd::PhaseTapChanger |
Phase tap changer associated with this transformer end.
IEC61970::Base::Wires::RatioTapChanger* IEC61970::Base::Wires::TransformerEnd::RatioTapChanger |
Ratio tap changer associated with this transformer end.
IEC61970::Base::Domain::Resistance IEC61970::Base::Wires::TransformerEnd::rground |
(for Yn and Zn connections) Resistance part of neutral impedance where 'grounded' is true.
IEC61970::Base::Wires::TransformerStarImpedance* IEC61970::Base::Wires::TransformerEnd::StarImpedance |
(accurate for 2- or 3-winding transformers only) Pi-model impedances of this transformer end. By convention, for a two winding transformer, the full values of the transformer should be entered on the high voltage end (endNumber=1).
IEC61970::Base::Core::Terminal* IEC61970::Base::Wires::TransformerEnd::Terminal |
Terminal of the power transformer to which this transformer end belongs.
IEC61970::Base::Domain::Reactance IEC61970::Base::Wires::TransformerEnd::xground |
(for Yn and Zn connections) Reactive part of neutral impedance where 'grounded' is true.