IEC61970 17v23
Public Attributes | List of all members
IEC61970::Dynamics::StandardModels::UnderexcitationLimiterDynamics::UnderexcLim2Simplified Class Reference

#include <UnderexcLim2Simplified.h>

Inheritance diagram for IEC61970::Dynamics::StandardModels::UnderexcitationLimiterDynamics::UnderexcLim2Simplified:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Dynamics::StandardModels::UnderexcitationLimiterDynamics::UnderexcLim2Simplified:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::PU kui
 
IEC61970::Base::Domain::PU p0
 
IEC61970::Base::Domain::PU p1
 
IEC61970::Base::Domain::PU q0
 
IEC61970::Base::Domain::PU q1
 
IEC61970::Base::Domain::PU vuimax
 
IEC61970::Base::Domain::PU vuimin
 
- Public Attributes inherited from IEC61970::Dynamics::StandardModels::UnderexcitationLimiterDynamics::UnderexcitationLimiterDynamics
IEC61970::Dynamics::StandardModels::ExcitationSystemDynamics::ExcitationSystemDynamicsExcitationSystemDynamics
 
IEC61970::Dynamics::StandardInterconnections::RemoteInputSignalRemoteInputSignal
 
- Public Attributes inherited from IEC61970::Dynamics::StandardModels::DynamicsFunctionBlock
IEC61970::Base::Domain::Boolean enabled
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

This model can be derived from UnderexcLimIEEE2. The limit characteristic (look –up table) is a single straight-line, the same as UnderexcLimIEEE2 (see Figure 10.4 (p 32), IEEE 421.5-2005 Section 10.2).

Member Data Documentation

◆ kui

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::UnderexcitationLimiterDynamics::UnderexcLim2Simplified::kui

Gain Under excitation limiter (Kui). Typical Value = 0.1.

◆ p0

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::UnderexcitationLimiterDynamics::UnderexcLim2Simplified::p0

Segment P initial point (P0). Typical Value = 0.

◆ p1

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::UnderexcitationLimiterDynamics::UnderexcLim2Simplified::p1

Segment P end point (P1). Typical Value = 1.

◆ q0

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::UnderexcitationLimiterDynamics::UnderexcLim2Simplified::q0

Segment Q initial point (Q0). Typical Value = -0.31.

◆ q1

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::UnderexcitationLimiterDynamics::UnderexcLim2Simplified::q1

Segment Q end point (Q1). Typical Value = -0.1.

◆ vuimax

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::UnderexcitationLimiterDynamics::UnderexcLim2Simplified::vuimax

Maximum error signal (VUImax). Typical Value = 1.

◆ vuimin

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::UnderexcitationLimiterDynamics::UnderexcLim2Simplified::vuimin

Minimum error signal (VUImin). Typical Value = 0.


The documentation for this class was generated from the following files: