IEC61970 17v23
Public Attributes | List of all members
IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC Class Reference

#include <GovSteamCC.h>

Inheritance diagram for IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::PU dhp
 
IEC61970::Base::Domain::PU dlp
 
IEC61970::Base::Domain::PU fhp
 
IEC61970::Base::Domain::PU flp
 
IEC61970::Base::Domain::ActivePower mwbase
 
IEC61970::Base::Domain::PU pmaxhp
 
IEC61970::Base::Domain::PU pmaxlp
 
IEC61970::Base::Domain::PU rhp
 
IEC61970::Base::Domain::PU rlp
 
IEC61970::Base::Domain::Seconds t1hp
 
IEC61970::Base::Domain::Seconds t1lp
 
IEC61970::Base::Domain::Seconds t3hp
 
IEC61970::Base::Domain::Seconds t3lp
 
IEC61970::Base::Domain::Seconds t4hp
 
IEC61970::Base::Domain::Seconds t4lp
 
IEC61970::Base::Domain::Seconds t5hp
 
IEC61970::Base::Domain::Seconds t5lp
 
- Public Attributes inherited from IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::TurbineGovernorDynamics
IEC61970::Dynamics::StandardModels::AsynchronousMachineDynamics::AsynchronousMachineDynamicsAsynchronousMachineDynamics
 
- Public Attributes inherited from IEC61970::Dynamics::StandardModels::DynamicsFunctionBlock
IEC61970::Base::Domain::Boolean enabled
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

Cross compound turbine governor model.

Member Data Documentation

◆ dhp

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::dhp

HP damping factor (Dhp). Typical Value = 0.

◆ dlp

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::dlp

LP damping factor (Dlp). Typical Value = 0.

◆ fhp

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::fhp

Fraction of HP power ahead of reheater (Fhp). Typical Value = 0.3.

◆ flp

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::flp

Fraction of LP power ahead of reheater (Flp). Typical Value = 0.7.

◆ mwbase

IEC61970::Base::Domain::ActivePower IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::mwbase

Base for power values (MWbase) (>0). Unit = MW.

◆ pmaxhp

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::pmaxhp

Maximum HP value position (Pmaxhp). Typical Value = 1.

◆ pmaxlp

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::pmaxlp

Maximum LP value position (Pmaxlp). Typical Value = 1.

◆ rhp

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::rhp

HP governor droop (Rhp). Typical Value = 0.05.

◆ rlp

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::rlp

LP governor droop (Rlp). Typical Value = 0.05.

◆ t1hp

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::t1hp

HP governor time constant (T1hp). Typical Value = 0.1.

◆ t1lp

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::t1lp

LP governor time constant (T1lp). Typical Value = 0.1.

◆ t3hp

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::t3hp

HP turbine time constant (T3hp). Typical Value = 0.1.

◆ t3lp

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::t3lp

LP turbine time constant (T3lp). Typical Value = 0.1.

◆ t4hp

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::t4hp

HP turbine time constant (T4hp). Typical Value = 0.1.

◆ t4lp

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::t4lp

LP turbine time constant (T4lp). Typical Value = 0.1.

◆ t5hp

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::t5hp

HP reheater time constant (T5hp). Typical Value = 10.

◆ t5lp

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamCC::t5lp

LP reheater time constant (T5lp). Typical Value = 10.


The documentation for this class was generated from the following files: