#include <PerLengthSequenceImpedance.h>


| Public Attributes | |
| IEC61970::Base::Domain::SusceptancePerLength | b0ch | 
| IEC61970::Base::Domain::SusceptancePerLength | bch | 
| IEC61970::Base::Domain::ConductancePerLength | g0ch | 
| IEC61970::Base::Domain::ConductancePerLength | gch | 
| IEC61970::Base::Domain::ResistancePerLength | r | 
| IEC61970::Base::Domain::ResistancePerLength | r0 | 
| IEC61970::Base::Domain::ReactancePerLength | x | 
| IEC61970::Base::Domain::ReactancePerLength | x0 | 
|  Public Attributes inherited from IEC61970::Base::Wires::PerLengthImpedance | |
| std::list< IEC61970::Base::Wires::ACLineSegment * > | ACLineSegments | 
|  Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject | |
| IEC61970::Base::Domain::String | aliasName | 
| IEC61970::Base::Domain::String | description | 
| IEC61970::Base::Domain::String | mRID | 
| IEC61970::Base::Domain::String | name | 
| std::list< IEC61970::Base::DiagramLayout::DiagramObject * > | DiagramObjects | 
Sequence impedance and admittance parameters per unit length, for transposed lines of 1, 2, or 3 phases. For 1-phase lines, define x=x0=xself. For 2-phase lines, define x=xs-xm and x0=xs+xm.
| IEC61970::Base::Domain::SusceptancePerLength IEC61970::Base::Wires::PerLengthSequenceImpedance::b0ch | 
Zero sequence shunt (charging) susceptance, per unit of length.
| IEC61970::Base::Domain::SusceptancePerLength IEC61970::Base::Wires::PerLengthSequenceImpedance::bch | 
Positive sequence shunt (charging) susceptance, per unit of length.
| IEC61970::Base::Domain::ConductancePerLength IEC61970::Base::Wires::PerLengthSequenceImpedance::g0ch | 
Zero sequence shunt (charging) conductance, per unit of length.
| IEC61970::Base::Domain::ConductancePerLength IEC61970::Base::Wires::PerLengthSequenceImpedance::gch | 
Positive sequence shunt (charging) conductance, per unit of length.
| IEC61970::Base::Domain::ResistancePerLength IEC61970::Base::Wires::PerLengthSequenceImpedance::r | 
Positive sequence series resistance, per unit of length.
| IEC61970::Base::Domain::ResistancePerLength IEC61970::Base::Wires::PerLengthSequenceImpedance::r0 | 
Zero sequence series resistance, per unit of length.
| IEC61970::Base::Domain::ReactancePerLength IEC61970::Base::Wires::PerLengthSequenceImpedance::x | 
Positive sequence series reactance, per unit of length.
| IEC61970::Base::Domain::ReactancePerLength IEC61970::Base::Wires::PerLengthSequenceImpedance::x0 | 
Zero sequence series reactance, per unit of length.
 1.8.13