#include <CombustionTurbine.h>


A prime mover that is typically fueled by gas or light oil.
| IEC61970::Base::Generation::Production::AirCompressor* IEC61970::Base::Generation::GenerationTrainingSimulation::CombustionTurbine::AirCompressor | 
A CAES air compressor is driven by combustion turbine.
| IEC61970::Base::Domain::Temperature IEC61970::Base::Generation::GenerationTrainingSimulation::CombustionTurbine::ambientTemp | 
Default ambient temperature to be used in modeling applications.
| IEC61970::Base::Domain::PU IEC61970::Base::Generation::GenerationTrainingSimulation::CombustionTurbine::auxPowerVersusFrequency | 
Off-nominal frequency effect on turbine auxiliaries. Per unit reduction in auxiliary active power consumption versus per unit reduction in frequency (from rated frequency).
| IEC61970::Base::Domain::PU IEC61970::Base::Generation::GenerationTrainingSimulation::CombustionTurbine::auxPowerVersusVoltage | 
Off-nominal voltage effect on turbine auxiliaries. Per unit reduction in auxiliary active power consumption versus per unit reduction in auxiliary bus voltage (from a specified voltage level).
| IEC61970::Base::Domain::PU IEC61970::Base::Generation::GenerationTrainingSimulation::CombustionTurbine::capabilityVersusFrequency | 
Off-nominal frequency effect on turbine capability. Per unit reduction in unit active power capability versus per unit reduction in frequency (from rated frequency).
| IEC61970::Base::Generation::GenerationTrainingSimulation::CTTempActivePowerCurve* IEC61970::Base::Generation::GenerationTrainingSimulation::CombustionTurbine::CTTempActivePowerCurve | 
A combustion turbine may have an active power versus ambient temperature relationship.
| IEC61970::Base::Domain::Boolean IEC61970::Base::Generation::GenerationTrainingSimulation::CombustionTurbine::heatRecoveryFlag | 
Flag that is set to true if the combustion turbine is associated with a heat recovery boiler.
| IEC61970::Base::Domain::PU IEC61970::Base::Generation::GenerationTrainingSimulation::CombustionTurbine::powerVariationByTemp | 
Per unit change in power per (versus) unit change in ambient temperature.
| IEC61970::Base::Domain::Temperature IEC61970::Base::Generation::GenerationTrainingSimulation::CombustionTurbine::referenceTemp | 
Reference temperature at which the output of the turbine was defined.
| IEC61970::Base::Domain::Seconds IEC61970::Base::Generation::GenerationTrainingSimulation::CombustionTurbine::timeConstant | 
The time constant for the turbine.