IEC61970::Base::Equivalents::EquivalentInjection Class Reference

#include <EquivalentInjection.h>

Inheritance diagram for IEC61970::Base::Equivalents::EquivalentInjection:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Base::Equivalents::EquivalentInjection:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::ActivePower maxP
 
IEC61970::Base::Domain::ReactivePower maxQ
 
IEC61970::Base::Domain::ActivePower minP
 
IEC61970::Base::Domain::ReactivePower minQ
 
IEC61970::Base::Domain::ActivePower p
 
IEC61970::Base::Domain::ReactivePower q
 
IEC61970::Base::Domain::Resistance r
 
IEC61970::Base::Domain::Resistance r0
 
IEC61970::Base::Domain::Resistance r2
 
IEC61970::Base::Domain::Boolean regulationCapability
 
IEC61970::Base::Domain::Boolean regulationStatus
 
IEC61970::Base::Domain::Voltage regulationTarget
 
IEC61970::Base::Domain::Reactance x
 
IEC61970::Base::Domain::Reactance x0
 
IEC61970::Base::Domain::Reactance x2
 
- Public Attributes inherited from IEC61970::Base::Core::Equipment
IEC61970::Base::Domain::Boolean aggregate
 
IEC61970::Base::Domain::Boolean inService
 
IEC61970::Base::Domain::Boolean networkAnalysisEnabled
 
IEC61970::Base::Domain::Boolean normallyInService
 
- Public Attributes inherited from IEC61970::Base::Core::PowerSystemResource
std::list< IEC61970::Base::Meas::Control * > Controls
 
std::list< IEC61970::Base::Meas::Measurement * > Measurements
 
IEC61970::Base::Core::PSRTypePSRType
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

This class represents equivalent injections (generation or load). Voltage regulation is allowed only at the point of connection.

Member Data Documentation

◆ maxP

IEC61970::Base::Domain::ActivePower IEC61970::Base::Equivalents::EquivalentInjection::maxP

Maximum active power of the injection.

◆ maxQ

IEC61970::Base::Domain::ReactivePower IEC61970::Base::Equivalents::EquivalentInjection::maxQ

Used for modeling of infeed for load flow exchange. Not used for short circuit modeling. If maxQ and minQ are not used ReactiveCapabilityCurve can be used.

◆ minP

IEC61970::Base::Domain::ActivePower IEC61970::Base::Equivalents::EquivalentInjection::minP

Minimum active power of the injection.

◆ minQ

IEC61970::Base::Domain::ReactivePower IEC61970::Base::Equivalents::EquivalentInjection::minQ

Used for modeling of infeed for load flow exchange. Not used for short circuit modeling. If maxQ and minQ are not used ReactiveCapabilityCurve can be used.

◆ p

IEC61970::Base::Domain::ActivePower IEC61970::Base::Equivalents::EquivalentInjection::p

Equivalent active power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for steady state solutions.

◆ q

IEC61970::Base::Domain::ReactivePower IEC61970::Base::Equivalents::EquivalentInjection::q

Equivalent reactive power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for steady state solutions.

◆ r

IEC61970::Base::Domain::Resistance IEC61970::Base::Equivalents::EquivalentInjection::r

Positive sequence resistance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange.

◆ r0

IEC61970::Base::Domain::Resistance IEC61970::Base::Equivalents::EquivalentInjection::r0

Zero sequence resistance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange.

◆ r2

IEC61970::Base::Domain::Resistance IEC61970::Base::Equivalents::EquivalentInjection::r2

Negative sequence resistance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange.

◆ regulationCapability

IEC61970::Base::Domain::Boolean IEC61970::Base::Equivalents::EquivalentInjection::regulationCapability

Specifies whether or not the EquivalentInjection has the capability to regulate the local voltage.

◆ regulationStatus

IEC61970::Base::Domain::Boolean IEC61970::Base::Equivalents::EquivalentInjection::regulationStatus

Specifies the default regulation status of the EquivalentInjection. True is regulating. False is not regulating.

◆ regulationTarget

IEC61970::Base::Domain::Voltage IEC61970::Base::Equivalents::EquivalentInjection::regulationTarget

The target voltage for voltage regulation.

◆ x

IEC61970::Base::Domain::Reactance IEC61970::Base::Equivalents::EquivalentInjection::x

Positive sequence reactance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange.

◆ x0

IEC61970::Base::Domain::Reactance IEC61970::Base::Equivalents::EquivalentInjection::x0

Zero sequence reactance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange.

◆ x2

IEC61970::Base::Domain::Reactance IEC61970::Base::Equivalents::EquivalentInjection::x2

Negative sequence reactance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange.


The documentation for this class was generated from the following files: