IEC61970 17v23
Public Attributes | List of all members
IEC61970::Base::DC::VsConverter Class Reference

#include <VsConverter.h>

Inheritance diagram for IEC61970::Base::DC::VsConverter:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Base::DC::VsConverter:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::AngleDegrees delta
 
IEC61970::Base::Domain::PU droop
 
IEC61970::Base::Domain::Resistance droopCompensation
 
IEC61970::Base::Domain::Float maxModulationIndex
 
IEC61970::Base::Domain::CurrentFlow maxValveCurrent
 
IEC61970::Base::DC::VsPpccControlKind pPccControl = IEC61970::Base::DC::VsPpccControlKind::_undef
 
IEC61970::Base::DC::VsQpccControlKind qPccControl = IEC61970::Base::DC::VsQpccControlKind::_undef
 
IEC61970::Base::Domain::PerCent qShare
 
IEC61970::Base::Domain::ReactivePower targetQpcc
 
IEC61970::Base::Domain::Voltage targetUpcc
 
IEC61970::Base::Domain::Voltage uv
 
IEC61970::Base::DC::VsCapabilityCurveCapabilityCurve
 
- Public Attributes inherited from IEC61970::Base::DC::ACDCConverter
IEC61970::Base::Domain::ApparentPower baseS
 
IEC61970::Base::Domain::CurrentFlow idc
 
IEC61970::Base::Domain::ActivePower idleLoss
 
IEC61970::Base::Domain::Voltage maxUdc
 
IEC61970::Base::Domain::Voltage minUdc
 
IEC61970::Base::Domain::Integer numberOfValves
 
IEC61970::Base::Domain::ActivePower p
 
IEC61970::Base::Domain::ActivePower poleLossP
 
IEC61970::Base::Domain::ReactivePower q
 
IEC61970::Base::Domain::Voltage ratedUdc
 
IEC61970::Base::Domain::Resistance resistiveLoss
 
IEC61970::Base::Domain::ActivePowerPerCurrentFlow switchingLoss
 
IEC61970::Base::Domain::ActivePower targetPpcc
 
IEC61970::Base::Domain::Voltage targetUdc
 
IEC61970::Base::Domain::Voltage uc
 
IEC61970::Base::Domain::Voltage udc
 
IEC61970::Base::Domain::Voltage valveU0
 
IEC61970::Base::Core::TerminalPccTerminal
 
- Public Attributes inherited from IEC61970::Base::Core::Equipment
IEC61970::Base::Domain::Boolean aggregate
 
IEC61970::Base::Domain::Boolean inService
 
IEC61970::Base::Domain::Boolean networkAnalysisEnabled
 
IEC61970::Base::Domain::Boolean normallyInService
 
- Public Attributes inherited from IEC61970::Base::Core::PowerSystemResource
std::list< IEC61970::Base::Meas::Control * > Controls
 
std::list< IEC61970::Base::Meas::Measurement * > Measurements
 
IEC61970::Base::Core::PSRTypePSRType
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

DC side of the voltage source converter (VSC).

Member Data Documentation

◆ CapabilityCurve

IEC61970::Base::DC::VsCapabilityCurve* IEC61970::Base::DC::VsConverter::CapabilityCurve

Capability curve of this converter.

◆ delta

IEC61970::Base::Domain::AngleDegrees IEC61970::Base::DC::VsConverter::delta

Angle between uf and uc. Converter state variable used in power flow.

◆ droop

IEC61970::Base::Domain::PU IEC61970::Base::DC::VsConverter::droop

Droop constant; pu value is obtained as D [kV/MW] x Sb / Ubdc.

◆ droopCompensation

IEC61970::Base::Domain::Resistance IEC61970::Base::DC::VsConverter::droopCompensation

Compensation constant. Used to compensate for voltage drop when controlling voltage at a distant bus.

◆ maxModulationIndex

IEC61970::Base::Domain::Float IEC61970::Base::DC::VsConverter::maxModulationIndex

The max quotient between the AC converter voltage (Uc) and DC voltage (Ud). A factor typically less than 1. VSC configuration data used in power flow.

◆ maxValveCurrent

IEC61970::Base::Domain::CurrentFlow IEC61970::Base::DC::VsConverter::maxValveCurrent

The maximum current through a valve. This current limit is the basis for calculating the capability diagram. VSC configuration data.

◆ pPccControl

IEC61970::Base::DC::VsPpccControlKind IEC61970::Base::DC::VsConverter::pPccControl = IEC61970::Base::DC::VsPpccControlKind::_undef

Kind of control of real power and/or DC voltage.

◆ qShare

IEC61970::Base::Domain::PerCent IEC61970::Base::DC::VsConverter::qShare

Reactive power sharing factor among parallel converters on Uac control.

◆ targetQpcc

IEC61970::Base::Domain::ReactivePower IEC61970::Base::DC::VsConverter::targetQpcc

Reactive power injection target in AC grid, at point of common coupling.

◆ targetUpcc

IEC61970::Base::Domain::Voltage IEC61970::Base::DC::VsConverter::targetUpcc

Voltage target in AC grid, at point of common coupling.

◆ uv

IEC61970::Base::Domain::Voltage IEC61970::Base::DC::VsConverter::uv

Line-to-line voltage on the valve side of the converter transformer. Converter state variable, result from power flow.