IEC61970 17v23
Public Attributes | List of all members
IEC61970::Base::AuxiliaryEquipment::PotentialTransformer Class Reference

#include <PotentialTransformer.h>

Inheritance diagram for IEC61970::Base::AuxiliaryEquipment::PotentialTransformer:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Base::AuxiliaryEquipment::PotentialTransformer:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::String accuracyClass
 
IEC61970::Base::Domain::Float nominalRatio
 
IEC61970::Base::Domain::String ptClass
 
IEC61970::Base::AuxiliaryEquipment::PotentialTransformerKind type = IEC61970::Base::AuxiliaryEquipment::PotentialTransformerKind::_undef
 
- Public Attributes inherited from IEC61970::Base::AuxiliaryEquipment::AuxiliaryEquipment
IEC61970::Base::Core::TerminalTerminal
 
- Public Attributes inherited from IEC61970::Base::Core::Equipment
IEC61970::Base::Domain::Boolean aggregate
 
IEC61970::Base::Domain::Boolean inService
 
IEC61970::Base::Domain::Boolean networkAnalysisEnabled
 
IEC61970::Base::Domain::Boolean normallyInService
 
- Public Attributes inherited from IEC61970::Base::Core::PowerSystemResource
std::list< IEC61970::Base::Meas::Control * > Controls
 
std::list< IEC61970::Base::Meas::Measurement * > Measurements
 
IEC61970::Base::Core::PSRTypePSRType
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

Instrument transformer (also known as Voltage Transformer) used to measure electrical qualities of the circuit that is being protected and/or monitored. Typically used as voltage transducer for the purpose of metering, protection, or sometimes auxiliary substation supply. A typical secondary voltage rating would be 120V.

Member Data Documentation

◆ accuracyClass

IEC61970::Base::Domain::String IEC61970::Base::AuxiliaryEquipment::PotentialTransformer::accuracyClass

PT accuracy classification.

◆ nominalRatio

IEC61970::Base::Domain::Float IEC61970::Base::AuxiliaryEquipment::PotentialTransformer::nominalRatio

Nominal ratio between the primary and secondary voltage.

◆ ptClass

IEC61970::Base::Domain::String IEC61970::Base::AuxiliaryEquipment::PotentialTransformer::ptClass

Potential transformer (PT) classification covering burden.

◆ type

IEC61970::Base::AuxiliaryEquipment::PotentialTransformerKind IEC61970::Base::AuxiliaryEquipment::PotentialTransformer::type = IEC61970::Base::AuxiliaryEquipment::PotentialTransformerKind::_undef

Potential transformer construction type.


The documentation for this class was generated from the following files: