IEC61970 17v07
Public Attributes | List of all members
IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1 Class Reference

#include <GovSteam1.h>

Inheritance diagram for IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::Frequency db1
 
IEC61970::Base::Domain::ActivePower db2
 
IEC61970::Base::Domain::Frequency eps
 
IEC61970::Base::Domain::PU gv1
 
IEC61970::Base::Domain::PU gv2
 
IEC61970::Base::Domain::PU gv3
 
IEC61970::Base::Domain::PU gv4
 
IEC61970::Base::Domain::PU gv5
 
IEC61970::Base::Domain::PU gv6
 
IEC61970::Base::Domain::PU k
 
IEC61970::Base::Domain::Float k1
 
IEC61970::Base::Domain::Float k2
 
IEC61970::Base::Domain::Float k3
 
IEC61970::Base::Domain::Float k4
 
IEC61970::Base::Domain::Float k5
 
IEC61970::Base::Domain::Float k6
 
IEC61970::Base::Domain::Float k7
 
IEC61970::Base::Domain::Float k8
 
IEC61970::Base::Domain::ActivePower mwbase
 
IEC61970::Base::Domain::PU pgv1
 
IEC61970::Base::Domain::PU pgv2
 
IEC61970::Base::Domain::PU pgv3
 
IEC61970::Base::Domain::PU pgv4
 
IEC61970::Base::Domain::PU pgv5
 
IEC61970::Base::Domain::PU pgv6
 
IEC61970::Base::Domain::PU pmax
 
IEC61970::Base::Domain::PU pmin
 
IEC61970::Base::Domain::Boolean sdb1
 
IEC61970::Base::Domain::Boolean sdb2
 
IEC61970::Base::Domain::Seconds t1
 
IEC61970::Base::Domain::Seconds t2
 
IEC61970::Base::Domain::Seconds t3
 
IEC61970::Base::Domain::Seconds t4
 
IEC61970::Base::Domain::Seconds t5
 
IEC61970::Base::Domain::Seconds t6
 
IEC61970::Base::Domain::Seconds t7
 
IEC61970::Base::Domain::Float uc
 
IEC61970::Base::Domain::Float uo
 
IEC61970::Base::Domain::Boolean valve
 
- Public Attributes inherited from IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::TurbineGovernorDynamics
IEC61970::Dynamics::StandardModels::AsynchronousMachineDynamics::AsynchronousMachineDynamicsAsynchronousMachineDynamics
 
- Public Attributes inherited from IEC61970::Dynamics::StandardModels::DynamicsFunctionBlock
IEC61970::Base::Domain::Boolean enabled
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

Steam turbine governor model, based on the GovSteamIEEE1 model (with optional deadband and nonlinear valve gain added).

Member Data Documentation

◆ db1

IEC61970::Base::Domain::Frequency IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::db1

Intentional deadband width (db1). Unit = Hz. Typical Value = 0.

◆ db2

IEC61970::Base::Domain::ActivePower IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::db2

Unintentional deadband (db2). Unit = MW. Typical Value = 0.

◆ eps

IEC61970::Base::Domain::Frequency IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::eps

Intentional db hysteresis (eps). Unit = Hz. Typical Value = 0.

◆ gv1

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::gv1

Nonlinear gain valve position point 1 (GV1). Typical Value = 0.

◆ gv2

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::gv2

Nonlinear gain valve position point 2 (GV2). Typical Value = 0.4.

◆ gv3

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::gv3

Nonlinear gain valve position point 3 (GV3). Typical Value = 0.5.

◆ gv4

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::gv4

Nonlinear gain valve position point 4 (GV4). Typical Value = 0.6.

◆ gv5

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::gv5

Nonlinear gain valve position point 5 (GV5). Typical Value = 1.

◆ gv6

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::gv6

Nonlinear gain valve position point 6 (GV6). Typical Value = 0.

◆ k

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::k

Governor gain (reciprocal of droop) (K) (>0). Typical Value = 25.

◆ k1

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::k1

Fraction of HP shaft power after first boiler pass (K1). Typical Value = 0.2.

◆ k2

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::k2

Fraction of LP shaft power after first boiler pass (K2). Typical Value = 0.

◆ k3

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::k3

Fraction of HP shaft power after second boiler pass (K3). Typical Value = 0.3.

◆ k4

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::k4

Fraction of LP shaft power after second boiler pass (K4). Typical Value = 0.

◆ k5

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::k5

Fraction of HP shaft power after third boiler pass (K5). Typical Value = 0.5.

◆ k6

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::k6

Fraction of LP shaft power after third boiler pass (K6). Typical Value = 0.

◆ k7

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::k7

Fraction of HP shaft power after fourth boiler pass (K7). Typical Value = 0.

◆ k8

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::k8

Fraction of LP shaft power after fourth boiler pass (K8). Typical Value = 0.

◆ mwbase

IEC61970::Base::Domain::ActivePower IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::mwbase

Base for power values (MWbase) (>0). Unit = MW.

◆ pgv1

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::pgv1

Nonlinear gain power value point 1 (Pgv1). Typical Value = 0.

◆ pgv2

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::pgv2

Nonlinear gain power value point 2 (Pgv2). Typical Value = 0.75.

◆ pgv3

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::pgv3

Nonlinear gain power value point 3 (Pgv3). Typical Value = 0.91.

◆ pgv4

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::pgv4

Nonlinear gain power value point 4 (Pgv4). Typical Value = 0.98.

◆ pgv5

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::pgv5

Nonlinear gain power value point 5 (Pgv5). Typical Value = 1.

◆ pgv6

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::pgv6

Nonlinear gain power value point 6 (Pgv6). Typical Value = 0.

◆ pmax

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::pmax

Maximum valve opening (Pmax) (> Pmin). Typical Value = 1.

◆ pmin

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::pmin

Minimum valve opening (Pmin) (>=0). Typical Value = 0.

◆ sdb1

IEC61970::Base::Domain::Boolean IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::sdb1

Intentional deadband indicator. true = intentional deadband is applied false = intentional deadband is not applied. Typical Value = true.

◆ sdb2

IEC61970::Base::Domain::Boolean IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::sdb2

Unintentional deadband location. true = intentional deadband is applied before point "A" false = intentional deadband is applied after point "A". Typical Value = true.

◆ t1

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::t1

Governor lag time constant (T1). Typical Value = 0.

◆ t2

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::t2

Governor lead time constant (T2). Typical Value = 0.

◆ t3

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::t3

Valve positioner time constant (T3) (>0). Typical Value = 0.1.

◆ t4

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::t4

Inlet piping/steam bowl time constant (T4). Typical Value = 0.3.

◆ t5

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::t5

Time constant of second boiler pass (T5). Typical Value = 5.

◆ t6

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::t6

Time constant of third boiler pass (T6). Typical Value = 0.5.

◆ t7

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::t7

Time constant of fourth boiler pass (T7). Typical Value = 0.

◆ uc

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::uc

Maximum valve closing velocity (Uc) (<0). Unit = PU/sec. Typical Value = -10.

◆ uo

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::uo

Maximum valve opening velocity (Uo) (>0). Unit = PU/sec. Typical Value = 1.

◆ valve

IEC61970::Base::Domain::Boolean IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam1::valve

Nonlinear valve characteristic. true = nonlinear valve characteristic is used false = nonlinear valve characteristic is not used. Typical Value = true.


The documentation for this class was generated from the following files: