#include <ReactiveCapabilityCurve.h>
Public Attributes | |
IEC61970::Base::Domain::Temperature | coolantTemperature |
IEC61970::Base::Domain::Pressure | hydrogenPressure |
std::list< IEC61970::Base::Equivalents::EquivalentInjection * > | EquivalentInjection |
std::list< IEC61970::Base::Wires::SynchronousMachine * > | InitiallyUsedBySynchronousMachines |
std::list< IEC61970::Base::Wires::SynchronousMachine * > | SynchronousMachines |
Public Attributes inherited from IEC61970::Base::Core::Curve | |
IEC61970::Base::Core::CurveStyle | curveStyle = IEC61970::Base::Core::CurveStyle::_undef |
IEC61970::Base::Domain::UnitMultiplier | xMultiplier = IEC61970::Base::Domain::UnitMultiplier::_undef |
IEC61970::Base::Domain::UnitSymbol | xUnit = IEC61970::Base::Domain::UnitSymbol::_undef |
IEC61970::Base::Domain::UnitMultiplier | y1Multiplier = IEC61970::Base::Domain::UnitMultiplier::_undef |
IEC61970::Base::Domain::UnitSymbol | y1Unit = IEC61970::Base::Domain::UnitSymbol::_undef |
IEC61970::Base::Domain::UnitMultiplier | y2Multiplier = IEC61970::Base::Domain::UnitMultiplier::_undef |
IEC61970::Base::Domain::UnitSymbol | y2Unit = IEC61970::Base::Domain::UnitSymbol::_undef |
IEC61970::Base::Domain::UnitMultiplier | y3Multiplier = IEC61970::Base::Domain::UnitMultiplier::_undef |
IEC61970::Base::Domain::UnitSymbol | y3Unit = IEC61970::Base::Domain::UnitSymbol::_undef |
std::list< IEC61970::Base::Core::CurveData * > | CurveDatas |
Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject | |
IEC61970::Base::Domain::String | aliasName |
IEC61970::Base::Domain::String | description |
IEC61970::Base::Domain::String | mRID |
IEC61970::Base::Domain::String | name |
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > | DiagramObjects |
Reactive power rating envelope versus the synchronous machine's active power, in both the generating and motoring modes. For each active power value there is a corresponding high and low reactive power limit value. Typically there will be a separate curve for each coolant condition, such as hydrogen pressure. The Y1 axis values represent reactive minimum and the Y2 axis values represent reactive maximum.
IEC61970::Base::Domain::Temperature IEC61970::Base::Wires::ReactiveCapabilityCurve::coolantTemperature |
The machine's coolant temperature (e.g., ambient air or stator circulating water).
std::list<IEC61970::Base::Equivalents::EquivalentInjection*> IEC61970::Base::Wires::ReactiveCapabilityCurve::EquivalentInjection |
The equivalent injection using this reactive capability curve.
IEC61970::Base::Domain::Pressure IEC61970::Base::Wires::ReactiveCapabilityCurve::hydrogenPressure |
The hydrogen coolant pressure
std::list<IEC61970::Base::Wires::SynchronousMachine*> IEC61970::Base::Wires::ReactiveCapabilityCurve::InitiallyUsedBySynchronousMachines |
Synchronous machines using this curve as default.
std::list<IEC61970::Base::Wires::SynchronousMachine*> IEC61970::Base::Wires::ReactiveCapabilityCurve::SynchronousMachines |
Synchronous machines using this curve.