IEC61970::Base::AuxiliaryEquipment::CurrentTransformer Class Reference

#include <CurrentTransformer.h>

Inheritance diagram for IEC61970::Base::AuxiliaryEquipment::CurrentTransformer:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Base::AuxiliaryEquipment::CurrentTransformer:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::String accuracyClass
 
IEC61970::Base::Domain::PerCent accuracyLimit
 
IEC61970::Base::Domain::ActivePower coreBurden
 
IEC61970::Base::Domain::String ctClass
 
IEC61970::Base::Domain::String usage
 
- Public Attributes inherited from IEC61970::Base::AuxiliaryEquipment::AuxiliaryEquipment
IEC61970::Base::Core::TerminalTerminal
 
- Public Attributes inherited from IEC61970::Base::Core::Equipment
IEC61970::Base::Domain::Boolean aggregate
 
IEC61970::Base::Domain::Boolean inService
 
IEC61970::Base::Domain::Boolean normallyInService
 
- Public Attributes inherited from IEC61970::Base::Core::PowerSystemResource
std::list< IEC61970::Base::Meas::Control * > Controls
 
std::list< IEC61970::Base::Meas::Measurement * > Measurements
 
IEC61970::Base::Core::PSRTypePSRType
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

Instrument transformer used to measure electrical qualities of the circuit that is being protected and/or monitored. Typically used as current transducer for the purpose of metering or protection. A typical secondary current rating would be 5A.

Member Data Documentation

◆ accuracyClass

IEC61970::Base::Domain::String IEC61970::Base::AuxiliaryEquipment::CurrentTransformer::accuracyClass

CT accuracy classification.

◆ accuracyLimit

IEC61970::Base::Domain::PerCent IEC61970::Base::AuxiliaryEquipment::CurrentTransformer::accuracyLimit

Percent of rated current for which the CT remains accurate within specified limits.

◆ coreBurden

IEC61970::Base::Domain::ActivePower IEC61970::Base::AuxiliaryEquipment::CurrentTransformer::coreBurden

Power burden of the CT core.

◆ ctClass

IEC61970::Base::Domain::String IEC61970::Base::AuxiliaryEquipment::CurrentTransformer::ctClass

CT classification; i.e. class 10P.

◆ usage

IEC61970::Base::Domain::String IEC61970::Base::AuxiliaryEquipment::CurrentTransformer::usage

Intended usage of the CT; i.e. metering, protection.