Public Attributes

IEC61970::Base::Domain::Temperature coolantTemperature
 
IEC61970::Base::Domain::Pressure hydrogenPressure
 
std::list< IEC61970::Base::Equivalents::EquivalentInjection * > EquivalentInjection
 
std::list< IEC61970::Base::Wires::SynchronousMachine * > InitiallyUsedBySynchronousMachines
 
std::list< IEC61970::Base::Wires::SynchronousMachine * > SynchronousMachines
 
- Public Attributes inherited from IEC61970::Base::Core::Curve
IEC61970::Base::Core::CurveStyle curveStyle
 
IEC61970::Base::Domain::UnitMultiplier xMultiplier
 
IEC61970::Base::Domain::UnitSymbol xUnit
 
IEC61970::Base::Domain::UnitMultiplier y1Multiplier
 
IEC61970::Base::Domain::UnitSymbol y1Unit
 
IEC61970::Base::Domain::UnitMultiplier y2Multiplier
 
IEC61970::Base::Domain::UnitSymbol y2Unit
 
IEC61970::Base::Domain::UnitMultiplier y3Multiplier
 
IEC61970::Base::Domain::UnitSymbol y3Unit
 
std::list< IEC61970::Base::Core::CurveData * > CurveDatas
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

Reactive power rating envelope versus the synchronous machine's active power, in both the generating and motoring modes. For each active power value there is a corresponding high and low reactive power limit value. Typically there will be a separate curve for each coolant condition, such as hydrogen pressure. The Y1 axis values represent reactive minimum and the Y2 axis values represent reactive maximum.

Member Data Documentation

IEC61970::Base::Domain::Temperature IEC61970::Base::Wires::ReactiveCapabilityCurve::coolantTemperature

The machine's coolant temperature (e.g., ambient air or stator circulating water).

std::list<IEC61970::Base::Equivalents::EquivalentInjection*> IEC61970::Base::Wires::ReactiveCapabilityCurve::EquivalentInjection

The equivalent injection using this reactive capability curve.

IEC61970::Base::Domain::Pressure IEC61970::Base::Wires::ReactiveCapabilityCurve::hydrogenPressure

The hydrogen coolant pressure

std::list<IEC61970::Base::Wires::SynchronousMachine*> IEC61970::Base::Wires::ReactiveCapabilityCurve::InitiallyUsedBySynchronousMachines

Synchronous machines using this curve as default.

std::list<IEC61970::Base::Wires::SynchronousMachine*> IEC61970::Base::Wires::ReactiveCapabilityCurve::SynchronousMachines

Synchronous machines using this curve.