CIM++ Adapted CIM_SINERGIEN Codebase
|
#include <EnergySource.h>
A generic equivalent for an energy supplier on a transmission or distribution voltage level.
IEC61970::Base::Domain::ActivePower IEC61970::Base::Wires::EnergySource::activePower |
High voltage source active injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for steady state solutions.
IEC61970::Base::Domain::Voltage IEC61970::Base::Wires::EnergySource::nominalVoltage |
Phase-to-phase nominal voltage.
IEC61970::Base::Domain::Resistance IEC61970::Base::Wires::EnergySource::r |
Positive sequence Thevenin resistance.
IEC61970::Base::Domain::Resistance IEC61970::Base::Wires::EnergySource::r0 |
Zero sequence Thevenin resistance.
IEC61970::Base::Domain::ReactivePower IEC61970::Base::Wires::EnergySource::reactivePower |
High voltage source reactive injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for steady state solutions.
IEC61970::Base::Domain::Resistance IEC61970::Base::Wires::EnergySource::rn |
Negative sequence Thevenin resistance.
IEC61970::Base::Domain::AngleRadians IEC61970::Base::Wires::EnergySource::voltageAngle |
Phase angle of a-phase open circuit.
IEC61970::Base::Domain::Voltage IEC61970::Base::Wires::EnergySource::voltageMagnitude |
Phase-to-phase open circuit voltage magnitude.
IEC61970::Base::Domain::Reactance IEC61970::Base::Wires::EnergySource::x |
Positive sequence Thevenin reactance.
IEC61970::Base::Domain::Reactance IEC61970::Base::Wires::EnergySource::x0 |
Zero sequence Thevenin reactance.
IEC61970::Base::Domain::Reactance IEC61970::Base::Wires::EnergySource::xn |
Negative sequence Thevenin reactance.