CIM++ Adapted CIM_SINERGIEN Codebase
|
#include <LoadResponseCharacteristic.h>
Public Attributes | |
IEC61970::Base::Domain::Boolean | exponentModel |
IEC61970::Base::Domain::Float | pConstantCurrent |
IEC61970::Base::Domain::Float | pConstantImpedance |
IEC61970::Base::Domain::Float | pConstantPower |
IEC61970::Base::Domain::Float | pFrequencyExponent |
IEC61970::Base::Domain::Float | pVoltageExponent |
IEC61970::Base::Domain::Float | qConstantCurrent |
IEC61970::Base::Domain::Float | qConstantImpedance |
IEC61970::Base::Domain::Float | qConstantPower |
IEC61970::Base::Domain::Float | qFrequencyExponent |
IEC61970::Base::Domain::Float | qVoltageExponent |
Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject | |
IEC61970::Base::Domain::String | aliasName |
IEC61970::Base::Domain::String | description |
IEC61970::Base::Domain::String | mRID |
IEC61970::Base::Domain::String | name |
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > | DiagramObjects |
Models the characteristic response of the load demand due to changes in system conditions such as voltage and frequency. This is not related to demand response.
If LoadResponseCharacteristic.exponentModel is True, the voltage exponents are specified and used as to calculate:
Active power component = Pnominal * (Voltage/cim:BaseVoltage.nominalVoltage) ** cim:LoadResponseCharacteristic.pVoltageExponent
Reactive power component = Qnominal * (Voltage/cim:BaseVoltage. nominalVoltage)** cim:LoadResponseCharacteristic.qVoltageExponent
Where * means "multiply" and ** is "raised to power of".
IEC61970::Base::Domain::Boolean IEC61970::Base::LoadModel::LoadResponseCharacteristic::exponentModel |
Indicates the exponential voltage dependency model is to be used. If false, the coefficient model is to be used. The exponential voltage dependency model consist of the attributes
IEC61970::Base::Domain::Float IEC61970::Base::LoadModel::LoadResponseCharacteristic::pConstantCurrent |
Portion of active power load modeled as constant current.
IEC61970::Base::Domain::Float IEC61970::Base::LoadModel::LoadResponseCharacteristic::pConstantImpedance |
Portion of active power load modeled as constant impedance.
IEC61970::Base::Domain::Float IEC61970::Base::LoadModel::LoadResponseCharacteristic::pConstantPower |
Portion of active power load modeled as constant power.
IEC61970::Base::Domain::Float IEC61970::Base::LoadModel::LoadResponseCharacteristic::pFrequencyExponent |
Exponent of per unit frequency effecting active power.
IEC61970::Base::Domain::Float IEC61970::Base::LoadModel::LoadResponseCharacteristic::pVoltageExponent |
Exponent of per unit voltage effecting real power.
IEC61970::Base::Domain::Float IEC61970::Base::LoadModel::LoadResponseCharacteristic::qConstantCurrent |
Portion of reactive power load modeled as constant current.
IEC61970::Base::Domain::Float IEC61970::Base::LoadModel::LoadResponseCharacteristic::qConstantImpedance |
Portion of reactive power load modeled as constant impedance.
IEC61970::Base::Domain::Float IEC61970::Base::LoadModel::LoadResponseCharacteristic::qConstantPower |
Portion of reactive power load modeled as constant power.
IEC61970::Base::Domain::Float IEC61970::Base::LoadModel::LoadResponseCharacteristic::qFrequencyExponent |
Exponent of per unit frequency effecting reactive power.
IEC61970::Base::Domain::Float IEC61970::Base::LoadModel::LoadResponseCharacteristic::qVoltageExponent |
Exponent of per unit voltage effecting reactive power.