IEC61968::InfIEC61968::InfAssetInfo::OldSwitchInfo Class Reference

#include <OldSwitchInfo.h>

Inheritance diagram for IEC61968::InfIEC61968::InfAssetInfo::OldSwitchInfo:
Inheritance graph
[legend]
Collaboration diagram for IEC61968::InfIEC61968::InfAssetInfo::OldSwitchInfo:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::Voltage dielectricStrength
 
IEC61970::Base::Domain::Boolean loadBreak
 
IEC61970::Base::Domain::CurrentFlow makingCapacity
 
IEC61970::Base::Domain::CurrentFlow minimumCurrent
 
IEC61970::Base::Domain::Integer poleCount
 
IEC61970::Base::Domain::Boolean remote
 
IEC61970::Base::Domain::CurrentFlow withstandCurrent
 
- Public Attributes inherited from IEC61968::AssetInfo::SwitchInfo
IEC61970::Base::Domain::CurrentFlow breakingCapacity
 
IEC61970::Base::Domain::Boolean isSinglePhase
 
IEC61970::Base::Domain::Boolean isUnganged
 
IEC61970::Base::Domain::CurrentFlow ratedCurrent
 
IEC61970::Base::Domain::Voltage ratedVoltage
 
- Public Attributes inherited from IEC61968::Assets::AssetInfo
std::list< IEC61970::Base::Core::PowerSystemResource * > PowerSystemResources
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

Properties of switch assets.

Member Data Documentation

◆ dielectricStrength

IEC61970::Base::Domain::Voltage IEC61968::InfIEC61968::InfAssetInfo::OldSwitchInfo::dielectricStrength

The maximum rms voltage that may be applied across an open contact without breaking down the dielectric properties of the switch in the open position.

◆ loadBreak

IEC61970::Base::Domain::Boolean IEC61968::InfIEC61968::InfAssetInfo::OldSwitchInfo::loadBreak

True if switch has load breaking capabiity. Unless specified false, this is always assumed to be true for breakers and reclosers.

◆ makingCapacity

IEC61970::Base::Domain::CurrentFlow IEC61968::InfIEC61968::InfAssetInfo::OldSwitchInfo::makingCapacity

The highest value of current the switch can make at the rated voltage under specified operating conditions without suffering significant deterioration of its performance.

◆ minimumCurrent

IEC61970::Base::Domain::CurrentFlow IEC61968::InfIEC61968::InfAssetInfo::OldSwitchInfo::minimumCurrent

The lowest value of current that the switch can make, carry and break in uninterrupted duty at the rated voltage under specified operating conditions without suffering significant deterioration of its performance.

◆ poleCount

IEC61970::Base::Domain::Integer IEC61968::InfIEC61968::InfAssetInfo::OldSwitchInfo::poleCount

Number of poles (i.e. of current carrying conductors that are switched).

◆ remote

IEC61970::Base::Domain::Boolean IEC61968::InfIEC61968::InfAssetInfo::OldSwitchInfo::remote

True if device is capable of being operated by remote control.

◆ withstandCurrent

IEC61970::Base::Domain::CurrentFlow IEC61968::InfIEC61968::InfAssetInfo::OldSwitchInfo::withstandCurrent

The highest value of current the switch can carry in the closed position at the rated voltage under specified operating conditions without suffering significant deterioration of its performance.