#include <CurrentTransformerInfo.h>
Properties of current transformer asset.
IEC61970::Base::Domain::String IEC61968::InfIEC61968::InfAssetInfo::CurrentTransformerInfo::accuracyClass |
CT accuracy classification.
IEC61970::Base::Domain::CurrentFlow IEC61968::InfIEC61968::InfAssetInfo::CurrentTransformerInfo::accuracyLimit |
Accuracy limit.
IEC61970::Base::Domain::Integer IEC61968::InfIEC61968::InfAssetInfo::CurrentTransformerInfo::coreCount |
Number of cores.
IEC61970::Base::Domain::CurrentFlow IEC61968::InfIEC61968::InfAssetInfo::CurrentTransformerInfo::kneePointCurrent |
Maximum primary current where the CT still displays linear characteristicts.
IEC61970::Base::Domain::Voltage IEC61968::InfIEC61968::InfAssetInfo::CurrentTransformerInfo::kneePointVoltage |
Maximum voltage across the secondary terminals where the CT still displays linear characteristicts.
IEC61968::InfIEC61968::InfCommon::Ratio IEC61968::InfIEC61968::InfAssetInfo::CurrentTransformerInfo::maxRatio |
Maximum ratio between the primary and secondary current.
IEC61968::InfIEC61968::InfCommon::Ratio IEC61968::InfIEC61968::InfAssetInfo::CurrentTransformerInfo::nominalRatio |
Nominal ratio between the primary and secondary current; i.e. 100:5.
IEC61970::Base::Domain::CurrentFlow IEC61968::InfIEC61968::InfAssetInfo::CurrentTransformerInfo::primaryFlsRating |
Full load secondary (FLS) rating for primary winding.
IEC61968::InfIEC61968::InfCommon::Ratio IEC61968::InfIEC61968::InfAssetInfo::CurrentTransformerInfo::primaryRatio |
Ratio for the primary winding tap changer.
IEC61970::Base::Domain::CurrentFlow IEC61968::InfIEC61968::InfAssetInfo::CurrentTransformerInfo::ratedCurrent |
Rated current on the primary side.
IEC61970::Base::Domain::CurrentFlow IEC61968::InfIEC61968::InfAssetInfo::CurrentTransformerInfo::secondaryFlsRating |
Full load secondary (FLS) rating for secondary winding.
IEC61968::InfIEC61968::InfCommon::Ratio IEC61968::InfIEC61968::InfAssetInfo::CurrentTransformerInfo::secondaryRatio |
Ratio for the secondary winding tap changer.
IEC61970::Base::Domain::CurrentFlow IEC61968::InfIEC61968::InfAssetInfo::CurrentTransformerInfo::tertiaryFlsRating |
Full load secondary (FLS) rating for tertiary winding.
IEC61968::InfIEC61968::InfCommon::Ratio IEC61968::InfIEC61968::InfAssetInfo::CurrentTransformerInfo::tertiaryRatio |
Ratio for the tertiary winding tap changer.
IEC61970::Base::Domain::String IEC61968::InfIEC61968::InfAssetInfo::CurrentTransformerInfo::usage |
Usage: eg. metering, protection, etc.