CIM++ Adapted CIM Codebase
Public Attributes | List of all members
IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic Class Reference

#include <LoadStatic.h>

Inheritance diagram for IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::Float ep1
 
IEC61970::Base::Domain::Float ep2
 
IEC61970::Base::Domain::Float ep3
 
IEC61970::Base::Domain::Float eq1
 
IEC61970::Base::Domain::Float eq2
 
IEC61970::Base::Domain::Float eq3
 
IEC61970::Base::Domain::Float kp1
 
IEC61970::Base::Domain::Float kp2
 
IEC61970::Base::Domain::Float kp3
 
IEC61970::Base::Domain::Float kp4
 
IEC61970::Base::Domain::Float kpf
 
IEC61970::Base::Domain::Float kq1
 
IEC61970::Base::Domain::Float kq2
 
IEC61970::Base::Domain::Float kq3
 
IEC61970::Base::Domain::Float kq4
 
IEC61970::Base::Domain::Float kqf
 
IEC61970::Dynamics::StandardModels::LoadDynamics::StaticLoadModelKind staticLoadModelType
 
IEC61970::Dynamics::StandardModels::LoadDynamics::LoadAggregateLoadAggregate
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

General static load model representing the sensitivity of the real and reactive power consumed by the load to the amplitude and frequency of the bus voltage.

Member Data Documentation

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::ep1

First term voltage exponent for active power (Ep1). Used only when . staticLoadModelType = exponential.

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::ep2

Second term voltage exponent for active power (Ep2). Used only when . staticLoadModelType = exponential.

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::ep3

Third term voltage exponent for active power (Ep3). Used only when . staticLoadModelType = exponential.

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::eq1

First term voltage exponent for reactive power (Eq1). Used only when . staticLoadModelType = exponential.

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::eq2

Second term voltage exponent for reactive power (Eq2). Used only when . staticLoadModelType = exponential.

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::eq3

Third term voltage exponent for reactive power (Eq3). Used only when . staticLoadModelType = exponential.

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::kp1

First term voltage coefficient for active power (Kp1). Not used when . staticLoadModelType = constantZ.

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::kp2

Second term voltage coefficient for active power (Kp2). Not used when . staticLoadModelType = constantZ.

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::kp3

Third term voltage coefficient for active power (Kp3). Not used when . staticLoadModelType = constantZ.

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::kp4

Frequency coefficient for active power (Kp4). Must be non-zero when . staticLoadModelType = ZIP2. Not used for all other values of . staticLoadModelType.

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::kpf

Frequency deviation coefficient for active power (Kpf). Not used when . staticLoadModelType = constantZ.

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::kq1

First term voltage coefficient for reactive power (Kq1). Not used when . staticLoadModelType = constantZ.

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::kq2

Second term voltage coefficient for reactive power (Kq2). Not used when . staticLoadModelType = constantZ.

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::kq3

Third term voltage coefficient for reactive power (Kq3). Not used when . staticLoadModelType = constantZ.

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::kq4

Frequency coefficient for reactive power (Kq4). Must be non-zero when . staticLoadModelType = ZIP2. Not used for all other values of . staticLoadModelType.

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::kqf

Frequency deviation coefficient for reactive power (Kqf). Not used when . staticLoadModelType = constantZ.

IEC61970::Dynamics::StandardModels::LoadDynamics::LoadAggregate* IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::LoadAggregate

Aggregate load to which this aggregate static load belongs.

IEC61970::Dynamics::StandardModels::LoadDynamics::StaticLoadModelKind IEC61970::Dynamics::StandardModels::LoadDynamics::LoadStatic::staticLoadModelType

Type of static load model. Typical Value = constantZ.


The documentation for this class was generated from the following files: