aggregate | IEC61970::Base::Core::Equipment | |
aliasName | IEC61970::Base::Core::IdentifiedObject | |
BaseClass() (defined in BaseClass) | BaseClass | inline |
ConductingEquipments | IEC61970::Base::Protection::ProtectionEquipment | |
Controls | IEC61970::Base::Core::PowerSystemResource | |
currentLimit1 | IEC61970::Base::Protection::CurrentRelay | |
currentLimit2 | IEC61970::Base::Protection::CurrentRelay | |
currentLimit3 | IEC61970::Base::Protection::CurrentRelay | |
CurrentRelay() (defined in IEC61970::Base::Protection::CurrentRelay) | IEC61970::Base::Protection::CurrentRelay | |
description | IEC61970::Base::Core::IdentifiedObject | |
DiagramObjects | IEC61970::Base::Core::IdentifiedObject | |
Equipment() (defined in IEC61970::Base::Core::Equipment) | IEC61970::Base::Core::Equipment | |
highLimit | IEC61970::Base::Protection::ProtectionEquipment | |
IdentifiedObject() (defined in IEC61970::Base::Core::IdentifiedObject) | IEC61970::Base::Core::IdentifiedObject | |
inService | IEC61970::Base::Core::Equipment | |
inverseTimeFlag | IEC61970::Base::Protection::CurrentRelay | |
lowLimit | IEC61970::Base::Protection::ProtectionEquipment | |
Measurements | IEC61970::Base::Core::PowerSystemResource | |
mRID | IEC61970::Base::Core::IdentifiedObject | |
name | IEC61970::Base::Core::IdentifiedObject | |
normallyInService | IEC61970::Base::Core::Equipment | |
powerDirectionFlag | IEC61970::Base::Protection::ProtectionEquipment | |
PowerSystemResource() (defined in IEC61970::Base::Core::PowerSystemResource) | IEC61970::Base::Core::PowerSystemResource | |
ProtectedSwitches | IEC61970::Base::Protection::ProtectionEquipment | |
ProtectionEquipment() (defined in IEC61970::Base::Protection::ProtectionEquipment) | IEC61970::Base::Protection::ProtectionEquipment | |
PSRType | IEC61970::Base::Core::PowerSystemResource | |
relayDelayTime | IEC61970::Base::Protection::ProtectionEquipment | |
timeDelay1 | IEC61970::Base::Protection::CurrentRelay | |
timeDelay2 | IEC61970::Base::Protection::CurrentRelay | |
timeDelay3 | IEC61970::Base::Protection::CurrentRelay | |
unitMultiplier | IEC61970::Base::Protection::ProtectionEquipment | |
unitSymbol | IEC61970::Base::Protection::ProtectionEquipment | |
~BaseClass() (defined in BaseClass) | BaseClass | inlinevirtual |
~CurrentRelay() (defined in IEC61970::Base::Protection::CurrentRelay) | IEC61970::Base::Protection::CurrentRelay | virtual |
~Equipment() (defined in IEC61970::Base::Core::Equipment) | IEC61970::Base::Core::Equipment | virtual |
~IdentifiedObject() (defined in IEC61970::Base::Core::IdentifiedObject) | IEC61970::Base::Core::IdentifiedObject | virtual |
~PowerSystemResource() (defined in IEC61970::Base::Core::PowerSystemResource) | IEC61970::Base::Core::PowerSystemResource | virtual |
~ProtectionEquipment() (defined in IEC61970::Base::Protection::ProtectionEquipment) | IEC61970::Base::Protection::ProtectionEquipment | virtual |