IEC61970 16v29a - IEC61968 12v08
Public Attributes | List of all members
IEC61970::Base::Topology::TopologicalNode Class Reference

#include <TopologicalNode.h>

Inheritance diagram for IEC61970::Base::Topology::TopologicalNode:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Base::Topology::TopologicalNode:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::ActivePower pInjection
 
IEC61970::Base::Domain::ReactivePower qInjection
 
IEC61970::Base::Core::ReportingSuperGroup::ReportingGroupReportingGroup
 
IEC61970::Base::Core::ConnectivityNodeContainerConnectivityNodeContainer
 
std::list< IEC61970::Base::Core::ConnectivityNode * > ConnectivityNodes
 
IEC61970::Base::Core::BaseVoltageBaseVoltage
 
std::list< IEC61970::Base::Core::Terminal * > Terminal
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

For a detailed substation model a topological node is a set of connectivity nodes that, in the current network state, are connected together through any type of closed switches, including jumpers. Topological nodes change as the current network state changes (i.e., switches, breakers, etc. change state). For a planning model, switch statuses are not used to form topological nodes. Instead they are manually created or deleted in a model builder tool. Topological nodes maintained this way are also called "busses".

Member Data Documentation

◆ BaseVoltage

IEC61970::Base::Core::BaseVoltage* IEC61970::Base::Topology::TopologicalNode::BaseVoltage

The base voltage of the topologocial node.

◆ ConnectivityNodeContainer

IEC61970::Base::Core::ConnectivityNodeContainer* IEC61970::Base::Topology::TopologicalNode::ConnectivityNodeContainer

The connectivity node container to which the toplogical node belongs.

◆ ConnectivityNodes

std::list<IEC61970::Base::Core::ConnectivityNode*> IEC61970::Base::Topology::TopologicalNode::ConnectivityNodes

The connectivity nodes combine together to form this topological node. May depend on the current state of switches in the network.

◆ pInjection

IEC61970::Base::Domain::ActivePower IEC61970::Base::Topology::TopologicalNode::pInjection

The active power injected into the bus at this location in addition to injections from equipment. Positive sign means injection into the TopologicalNode (bus). Starting value for a steady state solution.

◆ qInjection

IEC61970::Base::Domain::ReactivePower IEC61970::Base::Topology::TopologicalNode::qInjection

The reactive power injected into the bus at this location in addition to injections from equipment. Positive sign means injection into the TopologicalNode (bus). Starting value for a steady state solution.

◆ ReportingGroup

IEC61970::Base::Core::ReportingSuperGroup::ReportingGroup* IEC61970::Base::Topology::TopologicalNode::ReportingGroup

The reporting group to which the topological node belongs.

◆ Terminal

std::list<IEC61970::Base::Core::Terminal*> IEC61970::Base::Topology::TopologicalNode::Terminal

The terminals associated with the topological node. This can be used as an alternative to the connectivity node path to terminal, thus making it unneccesary to model connectivity nodes in some cases. Note that if connectivity nodes are in the model, this association would probably not be used as an input specification.


The documentation for this class was generated from the following files: