IEC61968::InfIEC61968::InfAssets::CoolingPowerRating Class Reference

#include <CoolingPowerRating.h>

Inheritance diagram for IEC61968::InfIEC61968::InfAssets::CoolingPowerRating:
Inheritance graph
[legend]
Collaboration diagram for IEC61968::InfIEC61968::InfAssets::CoolingPowerRating:
Collaboration graph
[legend]

Public Attributes

IEC61968::InfIEC61968::InfAssets::CoolingKind coolingKind = IEC61968::InfIEC61968::InfAssets::CoolingKind::_undef
 
IEC61970::Base::Domain::ApparentPower powerRating
 
IEC61970::Base::Domain::Integer stage
 
std::list< IEC61968::InfIEC61968::InfAssets::Reconditioning * > Reconditionings
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

There are often stages of power which are associated with stages of cooling. For instance, a transformer may be rated 121kV on the primary, 15kV on the secondary and 4kV on the tertiary winding. These are voltage ratings and the power ratings are generally the same for all three windings and independent of the voltage ratings, there are instances where the tertiary may have a lower power rating. For example, for three stages, the power rating may be 15/20/25 MVA and the cooling is OA/FA/FOA. The 15 MVA rating goes with the OA cooling (Oil and Air cooling). This is called the self cooled rating as there are no external cooling enhancements. The 20 MVA rating goes with the FA cooling (Forced Air cooling), this means that when the fans are running and thus enhancing the cooling characteristics, the transformer can operate at a power level of 20 MVA. The 25 MVA rating goes with the FOA cooling (Forced Oil and Air cooling), this means that when the fans and pumps are running and thus enhancing the cooling characteristics even more than before, the transformer can operate at a power level of 25 MVA. This 15/20/25 MVA does not state how the power is split between the various windings. It may be 25 MVA input on the primary, 25 MVA output on the secondary and 0 MVA output on the tertiary. It may also operate at 25 MVA input on the primary, 17 MVA output on the secondary and 8 MVA output on the tertiary.

Member Data Documentation

◆ coolingKind

IEC61968::InfIEC61968::InfAssets::CoolingKind IEC61968::InfIEC61968::InfAssets::CoolingPowerRating::coolingKind = IEC61968::InfIEC61968::InfAssets::CoolingKind::_undef

Kind of cooling system.

◆ powerRating

IEC61970::Base::Domain::ApparentPower IEC61968::InfIEC61968::InfAssets::CoolingPowerRating::powerRating

The power rating associated with type of cooling specified for this stage.

◆ stage

IEC61970::Base::Domain::Integer IEC61968::InfIEC61968::InfAssets::CoolingPowerRating::stage

Stage of cooling and associated power rating.


The documentation for this class was generated from the following files: