IEC61970 16v29a - IEC61968 12v08
Public Attributes | List of all members
IEC61968::AssetInfo::TransformerEndInfo Class Reference

#include <TransformerEndInfo.h>

Inheritance diagram for IEC61968::AssetInfo::TransformerEndInfo:
Inheritance graph
[legend]
Collaboration diagram for IEC61968::AssetInfo::TransformerEndInfo:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Wires::WindingConnection connectionKind = IEC61970::Base::Wires::WindingConnection::_undef
 
IEC61970::Base::Domain::ApparentPower emergencyS
 
IEC61970::Base::Domain::Integer endNumber
 
IEC61970::Base::Domain::Voltage insulationU
 
IEC61970::Base::Domain::Integer phaseAngleClock
 
IEC61970::Base::Domain::Resistance r
 
IEC61970::Base::Domain::ApparentPower ratedS
 
IEC61970::Base::Domain::Voltage ratedU
 
IEC61970::Base::Domain::ApparentPower shortTermS
 
IEC61970::Base::Wires::TransformerCoreAdmittanceCoreAdmittance
 
std::list< IEC61970::Base::Wires::TransformerMeshImpedance * > FromMeshImpedances
 
IEC61970::Base::Wires::TransformerStarImpedanceTransformerStarImpedance
 
std::list< IEC61970::Base::Wires::TransformerMeshImpedance * > ToMeshImpedances
 
- Public Attributes inherited from IEC61968::Assets::AssetInfo
std::list< IEC61970::Base::Core::PowerSystemResource * > PowerSystemResources
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

Transformer end data.

Member Data Documentation

◆ connectionKind

IEC61970::Base::Wires::WindingConnection IEC61968::AssetInfo::TransformerEndInfo::connectionKind = IEC61970::Base::Wires::WindingConnection::_undef

Kind of connection.

◆ CoreAdmittance

IEC61970::Base::Wires::TransformerCoreAdmittance* IEC61968::AssetInfo::TransformerEndInfo::CoreAdmittance

Core admittance calculated from this transformer end datasheet, representing magnetising current and core losses. The full values of the transformer should be supplied for one transformer end info only.

◆ emergencyS

IEC61970::Base::Domain::ApparentPower IEC61968::AssetInfo::TransformerEndInfo::emergencyS

Apparent power that the winding can carry under emergency conditions (also called long-term emergency power).

◆ endNumber

IEC61970::Base::Domain::Integer IEC61968::AssetInfo::TransformerEndInfo::endNumber

Number for this transformer end, corresponding to the end's order in the PowerTransformer.vectorGroup attribute. Highest voltage winding should be 1.

◆ FromMeshImpedances

std::list<IEC61970::Base::Wires::TransformerMeshImpedance*> IEC61968::AssetInfo::TransformerEndInfo::FromMeshImpedances

All mesh impedances between this 'to' and other 'from' transformer ends.

◆ insulationU

IEC61970::Base::Domain::Voltage IEC61968::AssetInfo::TransformerEndInfo::insulationU

Basic insulation level voltage rating.

◆ phaseAngleClock

IEC61970::Base::Domain::Integer IEC61968::AssetInfo::TransformerEndInfo::phaseAngleClock

Winding phase angle where 360 degrees are represented with clock hours, so the valid values are {0, ..., 11}. For example, to express the second winding in code 'Dyn11', set attributes as follows: 'endNumber'=2, 'connectionKind' = Yn and 'phaseAngleClock' = 11.

◆ r

IEC61970::Base::Domain::Resistance IEC61968::AssetInfo::TransformerEndInfo::r

DC resistance.

◆ ratedS

IEC61970::Base::Domain::ApparentPower IEC61968::AssetInfo::TransformerEndInfo::ratedS

Normal apparent power rating.

◆ ratedU

IEC61970::Base::Domain::Voltage IEC61968::AssetInfo::TransformerEndInfo::ratedU

Rated voltage: phase-phase for three-phase windings, and either phase-phase or phase-neutral for single-phase windings.

◆ shortTermS

IEC61970::Base::Domain::ApparentPower IEC61968::AssetInfo::TransformerEndInfo::shortTermS

Apparent power that this winding can carry for a short period of time (in emergency).

◆ ToMeshImpedances

std::list<IEC61970::Base::Wires::TransformerMeshImpedance*> IEC61968::AssetInfo::TransformerEndInfo::ToMeshImpedances

All mesh impedances between this 'from' and other 'to' transformer ends.

◆ TransformerStarImpedance

IEC61970::Base::Wires::TransformerStarImpedance* IEC61968::AssetInfo::TransformerEndInfo::TransformerStarImpedance

Transformer star impedance calculated from this transformer end datasheet.


The documentation for this class was generated from the following files: