#include <WindProtectionIEC.h>
Public Attributes | |
IEC61970::Base::Domain::PU | dfimax |
IEC61970::Base::Domain::PU | fover |
IEC61970::Base::Domain::PU | funder |
IEC61970::Base::Domain::Boolean | mzc |
IEC61970::Base::Domain::Seconds | tfma |
IEC61970::Base::Domain::PU | uover |
IEC61970::Base::Domain::PU | uunder |
IEC61970::Dynamics::StandardModels::WindDynamics::WindTurbineType3or4IEC * | WindTurbineType3or4IEC |
IEC61970::Dynamics::StandardModels::WindDynamics::WindTurbineType1or2IEC * | WindTurbineType1or2IEC |
Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject | |
IEC61970::Base::Domain::String | aliasName |
IEC61970::Base::Domain::String | description |
IEC61970::Base::Domain::String | mRID |
IEC61970::Base::Domain::String | name |
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > | DiagramObjects |
The grid protection model includes protection against over and under voltage, and against over and under frequency.
Reference: IEC Standard 614000-27-1 Section 5.6.6.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::dfimax |
Maximum rate of change of frequency (dFmax). It is type dependent parameter.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::fover |
Wind turbine over frequency protection activation threshold (fover). It is project dependent parameter.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::funder |
Wind turbine under frequency protection activation threshold (funder). It is project dependent parameter.
IEC61970::Base::Domain::Boolean IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::mzc |
Zero crossing measurement mode (Mzc). True = 1 if the WT protection system uses zero crossings to detect frequency – otherwise false = 0. It is type dependent parameter.
IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::tfma |
Time interval of moving average window (TfMA). It is type dependent parameter.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::uover |
Wind turbine over voltage protection activation threshold (uover). It is project dependent parameter.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::uunder |
Wind turbine under voltage protection activation threshold (uunder). It is project dependent parameter.
IEC61970::Dynamics::StandardModels::WindDynamics::WindTurbineType1or2IEC* IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::WindTurbineType1or2IEC |
Wind generator type 1 or 2 model with which this wind turbine protection model is associated.
IEC61970::Dynamics::StandardModels::WindDynamics::WindTurbineType3or4IEC* IEC61970::Dynamics::StandardModels::WindDynamics::WindProtectionIEC::WindTurbineType3or4IEC |
Wind generator type 3 or 4 model with which this wind turbine protection model is associated.