IEC61970 16v29a
Public Attributes | List of all members
IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU Class Reference

#include <GovSteamEU.h>

Inheritance diagram for IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::Float chc
 
IEC61970::Base::Domain::Float cho
 
IEC61970::Base::Domain::PU cic
 
IEC61970::Base::Domain::PU cio
 
IEC61970::Base::Domain::PU db1
 
IEC61970::Base::Domain::PU db2
 
IEC61970::Base::Domain::PU hhpmax
 
IEC61970::Base::Domain::PU ke
 
IEC61970::Base::Domain::PU kfcor
 
IEC61970::Base::Domain::PU khp
 
IEC61970::Base::Domain::PU klp
 
IEC61970::Base::Domain::PU kwcor
 
IEC61970::Base::Domain::ActivePower mwbase
 
IEC61970::Base::Domain::PU pmax
 
IEC61970::Base::Domain::PU prhmax
 
IEC61970::Base::Domain::PU simx
 
IEC61970::Base::Domain::Seconds tb
 
IEC61970::Base::Domain::Seconds tdp
 
IEC61970::Base::Domain::Seconds ten
 
IEC61970::Base::Domain::Seconds tf
 
IEC61970::Base::Domain::Seconds tfp
 
IEC61970::Base::Domain::Seconds thp
 
IEC61970::Base::Domain::Seconds tip
 
IEC61970::Base::Domain::Seconds tlp
 
IEC61970::Base::Domain::Seconds tp
 
IEC61970::Base::Domain::Seconds trh
 
IEC61970::Base::Domain::Seconds tvhp
 
IEC61970::Base::Domain::Seconds tvip
 
IEC61970::Base::Domain::Seconds tw
 
IEC61970::Base::Domain::PU wfmax
 
IEC61970::Base::Domain::PU wfmin
 
IEC61970::Base::Domain::PU wmax1
 
IEC61970::Base::Domain::PU wmax2
 
IEC61970::Base::Domain::PU wwmax
 
IEC61970::Base::Domain::PU wwmin
 
- Public Attributes inherited from IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::TurbineGovernorDynamics
IEC61970::Dynamics::StandardModels::AsynchronousMachineDynamics::AsynchronousMachineDynamicsAsynchronousMachineDynamics
 
- Public Attributes inherited from IEC61970::Dynamics::StandardModels::DynamicsFunctionBlock
IEC61970::Base::Domain::Boolean enabled
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

Simplified model of boiler and steam turbine with PID governor.

Member Data Documentation

◆ chc

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::chc

Control valves rate closing limit (Chc). Unit = PU/sec. Typical Value = -3.3.

◆ cho

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::cho

Control valves rate opening limit (Cho). Unit = PU/sec. Typical Value = 0.17.

◆ cic

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::cic

Intercept valves rate closing limit (Cic). Typical Value = -2.2.

◆ cio

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::cio

Intercept valves rate opening limit (Cio). Typical Value = 0.123.

◆ db1

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::db1

Dead band of the frequency corrector (db1). Typical Value = 0.

◆ db2

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::db2

Dead band of the speed governor (db2). Typical Value = 0.0004.

◆ hhpmax

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::hhpmax

Maximum control valve position (Hhpmax). Typical Value = 1.

◆ ke

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::ke

Gain of the power controller (Ke). Typical Value = 0.65.

◆ kfcor

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::kfcor

Gain of the frequency corrector (Kfcor). Typical Value = 20.

◆ khp

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::khp

Fraction of total turbine output generated by HP part (Khp). Typical Value = 0. 277.

◆ klp

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::klp

Fraction of total turbine output generated by HP part (Klp). Typical Value = 0. 723.

◆ kwcor

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::kwcor

Gain of the speed governor (Kwcor). Typical Value = 20.

◆ mwbase

IEC61970::Base::Domain::ActivePower IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::mwbase

Base for power values (MWbase) (>0). Unit = MW.

◆ pmax

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::pmax

Maximal active power of the turbine (Pmax). Typical Value = 1.

◆ prhmax

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::prhmax

Maximum low pressure limit (Prhmax). Typical Value = 1.4.

◆ simx

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::simx

Intercept valves transfer limit (Simx). Typical Value = 0.425.

◆ tb

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::tb

Boiler time constant (Tb). Typical Value = 100.

◆ tdp

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::tdp

Derivative time constant of the power controller (Tdp). Typical Value = 0.

◆ ten

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::ten

Electro hydraulic transducer (Ten). Typical Value = 0.1.

◆ tf

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::tf

Frequency transducer time constant (Tf). Typical Value = 0.

◆ tfp

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::tfp

Time constant of the power controller (Tfp). Typical Value = 0.

◆ thp

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::thp

High pressure (HP) time constant of the turbine (Thp). Typical Value = 0.31.

◆ tip

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::tip

Integral time constant of the power controller (Tip). Typical Value = 2.

◆ tlp

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::tlp

Low pressure(LP) time constant of the turbine (Tlp). Typical Value = 0.45.

◆ tp

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::tp

Power transducer time constant (Tp). Typical Value = 0.07.

◆ trh

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::trh

Reheater time constant of the turbine (Trh). Typical Value = 8.

◆ tvhp

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::tvhp

Control valves servo time constant (Tvhp). Typical Value = 0.1.

◆ tvip

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::tvip

Intercept valves servo time constant (Tvip). Typical Value = 0.15.

◆ tw

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::tw

Speed transducer time constant (Tw). Typical Value = 0.02.

◆ wfmax

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::wfmax

Upper limit for frequency correction (Wfmax). Typical Value = 0.05.

◆ wfmin

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::wfmin

Lower limit for frequency correction (Wfmin). Typical Value = -0.05.

◆ wmax1

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::wmax1

Emergency speed control lower limit (wmax1). Typical Value = 1.025.

◆ wmax2

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::wmax2

Emergency speed control upper limit (wmax2). Typical Value = 1.05.

◆ wwmax

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::wwmax

Upper limit for the speed governor (Wwmax). Typical Value = 0.1.

◆ wwmin

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteamEU::wwmin

Lower limit for the speed governor frequency correction (Wwmin). Typical Value = -1.


The documentation for this class was generated from the following files: