#include <GovSteam0.h>
Public Attributes | |
IEC61970::Base::Domain::PU | dt |
IEC61970::Base::Domain::ActivePower | mwbase |
IEC61970::Base::Domain::PU | r |
IEC61970::Base::Domain::Seconds | t1 |
IEC61970::Base::Domain::Seconds | t2 |
IEC61970::Base::Domain::Seconds | t3 |
IEC61970::Base::Domain::PU | vmax |
IEC61970::Base::Domain::PU | vmin |
Public Attributes inherited from IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::TurbineGovernorDynamics | |
IEC61970::Dynamics::StandardModels::AsynchronousMachineDynamics::AsynchronousMachineDynamics * | AsynchronousMachineDynamics |
Public Attributes inherited from IEC61970::Dynamics::StandardModels::DynamicsFunctionBlock | |
IEC61970::Base::Domain::Boolean | enabled |
Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject | |
IEC61970::Base::Domain::String | aliasName |
IEC61970::Base::Domain::String | description |
IEC61970::Base::Domain::String | mRID |
IEC61970::Base::Domain::String | name |
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > | DiagramObjects |
A simplified steam turbine governor model.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam0::dt |
Turbine damping coefficient (Dt). Unit = delta P / delta speed. Typical Value = 0.
IEC61970::Base::Domain::ActivePower IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam0::mwbase |
Base for power values (MWbase) (>0). Unit = MW.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam0::r |
Permanent droop (R). Typical Value = 0.05.
IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam0::t1 |
Steam bowl time constant (T1). Typical Value = 0.5.
IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam0::t2 |
Numerator time constant of T2/T3 block (T2). Typical Value = 3.
IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam0::t3 |
Reheater time constant (T3). Typical Value = 10.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam0::vmax |
Maximum valve position, PU of mwcap (Vmax). Typical Value = 1.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovSteam0::vmin |
Minimum valve position, PU of mwcap (Vmin). Typical Value = 0.