IEC61970 16v29a
Public Attributes | List of all members
IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH Class Reference

#include <GovHydroWEH.h>

Inheritance diagram for IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::PU db
 
IEC61970::Base::Domain::PU dicn
 
IEC61970::Base::Domain::PU dpv
 
IEC61970::Base::Domain::PU dturb
 
IEC61970::Base::Domain::Boolean feedbackSignal
 
IEC61970::Base::Domain::PU fl1
 
IEC61970::Base::Domain::PU fl2
 
IEC61970::Base::Domain::PU fl3
 
IEC61970::Base::Domain::PU fl4
 
IEC61970::Base::Domain::PU fl5
 
IEC61970::Base::Domain::PU fp1
 
IEC61970::Base::Domain::PU fp10
 
IEC61970::Base::Domain::PU fp2
 
IEC61970::Base::Domain::PU fp3
 
IEC61970::Base::Domain::PU fp4
 
IEC61970::Base::Domain::PU fp5
 
IEC61970::Base::Domain::PU fp6
 
IEC61970::Base::Domain::PU fp7
 
IEC61970::Base::Domain::PU fp8
 
IEC61970::Base::Domain::PU fp9
 
IEC61970::Base::Domain::PU gmax
 
IEC61970::Base::Domain::PU gmin
 
IEC61970::Base::Domain::PU gtmxcl
 
IEC61970::Base::Domain::PU gtmxop
 
IEC61970::Base::Domain::PU gv1
 
IEC61970::Base::Domain::PU gv2
 
IEC61970::Base::Domain::PU gv3
 
IEC61970::Base::Domain::PU gv4
 
IEC61970::Base::Domain::PU gv5
 
IEC61970::Base::Domain::PU kd
 
IEC61970::Base::Domain::PU ki
 
IEC61970::Base::Domain::PU kp
 
IEC61970::Base::Domain::ActivePower mwbase
 
IEC61970::Base::Domain::PU pmss1
 
IEC61970::Base::Domain::PU pmss10
 
IEC61970::Base::Domain::PU pmss2
 
IEC61970::Base::Domain::PU pmss3
 
IEC61970::Base::Domain::PU pmss4
 
IEC61970::Base::Domain::PU pmss5
 
IEC61970::Base::Domain::PU pmss6
 
IEC61970::Base::Domain::PU pmss7
 
IEC61970::Base::Domain::PU pmss8
 
IEC61970::Base::Domain::PU pmss9
 
IEC61970::Base::Domain::Float rpg
 
IEC61970::Base::Domain::Float rpp
 
IEC61970::Base::Domain::Seconds td
 
IEC61970::Base::Domain::Seconds tdv
 
IEC61970::Base::Domain::Seconds tg
 
IEC61970::Base::Domain::Seconds tp
 
IEC61970::Base::Domain::Seconds tpe
 
IEC61970::Base::Domain::Seconds tw
 
- Public Attributes inherited from IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::TurbineGovernorDynamics
IEC61970::Dynamics::StandardModels::AsynchronousMachineDynamics::AsynchronousMachineDynamicsAsynchronousMachineDynamics
 
- Public Attributes inherited from IEC61970::Dynamics::StandardModels::DynamicsFunctionBlock
IEC61970::Base::Domain::Boolean enabled
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

Woodward Electric Hydro Governor Model.

Member Data Documentation

◆ db

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::db

Speed Dead Band (db).

◆ dicn

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::dicn

Value to allow the integral controller to advance beyond the gate limits (Dicn).

◆ dpv

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::dpv

Value to allow the Pilot valve controller to advance beyond the gate limits (Dpv).

◆ dturb

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::dturb

Turbine damping factor (Dturb). Unit = delta P (PU of MWbase) / delta speed (PU).

◆ feedbackSignal

IEC61970::Base::Domain::Boolean IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::feedbackSignal

Feedback signal selection (Sw). true = PID Output (if R-Perm-Gate=droop and R-Perm-Pe=0) false = Electrical Power (if R-Perm-Gate=0 and R-Perm-Pe=droop) or false = Gate Position (if R-Perm-Gate=droop and R-Perm-Pe=0).

◆ fl1

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::fl1

Flow Gate 1 (Fl1). Flow value for gate position point 1 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow.

◆ fl2

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::fl2

Flow Gate 2 (Fl2). Flow value for gate position point 2 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow.

◆ fl3

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::fl3

Flow Gate 3 (Fl3). Flow value for gate position point 3 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow.

◆ fl4

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::fl4

Flow Gate 4 (Fl4). Flow value for gate position point 4 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow.

◆ fl5

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::fl5

Flow Gate 5 (Fl5). Flow value for gate position point 5 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow.

◆ fp1

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::fp1

Flow P1 (Fp1). Turbine Flow value for point 1 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ fp10

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::fp10

Flow P10 (Fp10). Turbine Flow value for point 10 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ fp2

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::fp2

Flow P2 (Fp2). Turbine Flow value for point 2 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ fp3

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::fp3

Flow P3 (Fp3). Turbine Flow value for point 3 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ fp4

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::fp4

Flow P4 (Fp4). Turbine Flow value for point 4 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ fp5

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::fp5

Flow P5 (Fp5). Turbine Flow value for point 5 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ fp6

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::fp6

Flow P6 (Fp6). Turbine Flow value for point 6 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ fp7

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::fp7

Flow P7 (Fp7). Turbine Flow value for point 7 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ fp8

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::fp8

Flow P8 (Fp8). Turbine Flow value for point 8 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ fp9

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::fp9

Flow P9 (Fp9). Turbine Flow value for point 9 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ gmax

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::gmax

Maximum Gate Position (Gmax).

◆ gmin

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::gmin

Minimum Gate Position (Gmin).

◆ gtmxcl

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::gtmxcl

Maximum gate closing rate (Gtmxcl).

◆ gtmxop

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::gtmxop

Maximum gate opening rate (Gtmxop).

◆ gv1

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::gv1

Gate 1 (Gv1). Gate Position value for point 1 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow.

◆ gv2

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::gv2

Gate 2 (Gv2). Gate Position value for point 2 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow.

◆ gv3

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::gv3

Gate 3 (Gv3). Gate Position value for point 3 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow.

◆ gv4

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::gv4

Gate 4 (Gv4). Gate Position value for point 4 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow.

◆ gv5

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::gv5

Gate 5 (Gv5). Gate Position value for point 5 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow.

◆ kd

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::kd

Derivative controller derivative gain (Kd).

◆ ki

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::ki

Derivative controller Integral gain (Ki).

◆ kp

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::kp

Derivative control gain (Kp).

◆ mwbase

IEC61970::Base::Domain::ActivePower IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::mwbase

Base for power values (MWbase) (>0). Unit = MW.

◆ pmss1

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::pmss1

Pmss Flow P1 (Pmss1). Mechanical Power output Pmss for Turbine Flow point 1 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ pmss10

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::pmss10

Pmss Flow P10 (Pmss10). Mechanical Power output Pmss for Turbine Flow point 10 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ pmss2

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::pmss2

Pmss Flow P2 (Pmss2). Mechanical Power output Pmss for Turbine Flow point 2 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ pmss3

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::pmss3

Pmss Flow P3 (Pmss3). Mechanical Power output Pmss for Turbine Flow point 3 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ pmss4

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::pmss4

Pmss Flow P4 (Pmss4). Mechanical Power output Pmss for Turbine Flow point 4 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ pmss5

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::pmss5

Pmss Flow P5 (Pmss5). Mechanical Power output Pmss for Turbine Flow point 5 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ pmss6

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::pmss6

Pmss Flow P6 (Pmss6). Mechanical Power output Pmss for Turbine Flow point 6 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ pmss7

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::pmss7

Pmss Flow P7 (Pmss7). Mechanical Power output Pmss for Turbine Flow point 7 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ pmss8

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::pmss8

Pmss Flow P8 (Pmss8). Mechanical Power output Pmss for Turbine Flow point 8 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ pmss9

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::pmss9

Pmss Flow P9 (Pmss9). Mechanical Power output Pmss for Turbine Flow point 9 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow.

◆ rpg

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::rpg

Permanent droop for governor output feedback (R-Perm-Gate).

◆ rpp

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::rpp

Permanent droop for electrical power feedback (R-Perm-Pe).

◆ td

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::td

Derivative controller time constant to limit the derivative characteristic beyond a breakdown frequency to avoid amplification of high-frequency noise (Td).

◆ tdv

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::tdv

Distributive Valve time lag time constant (Tdv).

◆ tg

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::tg

Value to allow the Distribution valve controller to advance beyond the gate movement rate limit (Tg).

◆ tp

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::tp

Pilot Valve time lag time constant (Tp).

◆ tpe

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::tpe

Electrical power droop time constant (Tpe).

◆ tw

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovHydroWEH::tw

Water inertia time constant (Tw) (>0).


The documentation for this class was generated from the following files: