Public Attributes

IEC61970::Base::Domain::Float a
 
IEC61970::Base::Domain::Float b
 
IEC61970::Base::Domain::Frequency db1
 
IEC61970::Base::Domain::ActivePower db2
 
IEC61970::Base::Domain::Frequency eps
 
IEC61970::Base::Domain::PU fidle
 
IEC61970::Base::Domain::PU gv1
 
IEC61970::Base::Domain::PU gv2
 
IEC61970::Base::Domain::PU gv3
 
IEC61970::Base::Domain::PU gv4
 
IEC61970::Base::Domain::PU gv5
 
IEC61970::Base::Domain::PU gv6
 
IEC61970::Base::Domain::PU ka
 
IEC61970::Base::Domain::PU kt
 
IEC61970::Base::Domain::PU lmax
 
IEC61970::Base::Domain::PU loadinc
 
IEC61970::Base::Domain::Float ltrate
 
IEC61970::Base::Domain::ActivePower mwbase
 
IEC61970::Base::Domain::PU pgv1
 
IEC61970::Base::Domain::PU pgv2
 
IEC61970::Base::Domain::PU pgv3
 
IEC61970::Base::Domain::PU pgv4
 
IEC61970::Base::Domain::PU pgv5
 
IEC61970::Base::Domain::PU pgv6
 
IEC61970::Base::Domain::PU r
 
IEC61970::Base::Domain::Float rmax
 
IEC61970::Base::Domain::Seconds t1
 
IEC61970::Base::Domain::Seconds t2
 
IEC61970::Base::Domain::Seconds t3
 
IEC61970::Base::Domain::Seconds t4
 
IEC61970::Base::Domain::Seconds t5
 
IEC61970::Base::Domain::Seconds tltr
 
IEC61970::Base::Domain::PU vmax
 
IEC61970::Base::Domain::PU vmin
 
- Public Attributes inherited from IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::TurbineGovernorDynamics
IEC61970::Dynamics::StandardModels::AsynchronousMachineDynamics::AsynchronousMachineDynamicsAsynchronousMachineDynamics
 
- Public Attributes inherited from IEC61970::Dynamics::StandardModels::DynamicsFunctionBlock
IEC61970::Base::Domain::Boolean enabled
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

Modified single shaft gas turbine.

Member Data Documentation

◆ a

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::a

Turbine power time constant numerator scale factor (a). Typical Value = 0.8.

◆ b

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::b

Turbine power time constant denominator scale factor (b). Typical Value = 1.

◆ db1

IEC61970::Base::Domain::Frequency IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::db1

Intentional dead-band width (db1). Unit = Hz. Typical Value = 0.

◆ db2

IEC61970::Base::Domain::ActivePower IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::db2

Unintentional dead-band (db2). Unit = MW. Typical Value = 0.

◆ eps

IEC61970::Base::Domain::Frequency IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::eps

Intentional db hysteresis (eps). Unit = Hz. Typical Value = 0.

◆ fidle

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::fidle

Fuel flow at zero power output (Fidle). Typical Value = 0.18.

◆ gv1

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::gv1

Nonlinear gain point 1, PU gv (Gv1). Typical Value = 0.

◆ gv2

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::gv2

Nonlinear gain point 2,PU gv (Gv2). Typical Value = 0.

◆ gv3

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::gv3

Nonlinear gain point 3, PU gv (Gv3). Typical Value = 0.

◆ gv4

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::gv4

Nonlinear gain point 4, PU gv (Gv4). Typical Value = 0.

◆ gv5

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::gv5

Nonlinear gain point 5, PU gv (Gv5). Typical Value = 0.

◆ gv6

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::gv6

Nonlinear gain point 6, PU gv (Gv6). Typical Value = 0.

◆ ka

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::ka

Governor gain (Ka). Typical Value = 0.

◆ kt

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::kt

Temperature limiter gain (Kt). Typical Value = 3.

◆ lmax

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::lmax

Ambient temperature load limit (Lmax). Lmax is the turbine power output corresponding to the limiting exhaust gas temperature. Typical Value = 1.

◆ loadinc

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::loadinc

Valve position change allowed at fast rate (Loadinc). Typical Value = 0.05.

◆ ltrate

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::ltrate

Maximum long term fuel valve opening rate (Ltrate). Typical Value = 0.02.

◆ mwbase

IEC61970::Base::Domain::ActivePower IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::mwbase

Base for power values (MWbase) (> 0). Unit = MW.

◆ pgv1

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::pgv1

Nonlinear gain point 1, PU power (Pgv1). Typical Value = 0.

◆ pgv2

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::pgv2

Nonlinear gain point 2, PU power (Pgv2). Typical Value = 0.

◆ pgv3

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::pgv3

Nonlinear gain point 3, PU power (Pgv3). Typical Value = 0.

◆ pgv4

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::pgv4

Nonlinear gain point 4, PU power (Pgv4). Typical Value = 0.

◆ pgv5

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::pgv5

Nonlinear gain point 5, PU power (Pgv5). Typical Value = 0.

◆ pgv6

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::pgv6

Nonlinear gain point 6, PU power (Pgv6). Typical Value = 0.

◆ r

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::r

Permanent droop (R). Typical Value = 0.04.

◆ rmax

IEC61970::Base::Domain::Float IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::rmax

Maximum fuel valve opening rate (Rmax). Unit = PU/sec. Typical Value = 1.

◆ t1

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::t1

Governor mechanism time constant (T1). T1 represents the natural valve positioning time constant of the governor for small disturbances, as seen when rate limiting is not in effect. Typical Value = 0.5.

◆ t2

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::t2

Turbine power time constant (T2). T2 represents delay due to internal energy storage of the gas turbine engine. T2 can be used to give a rough approximation to the delay associated with acceleration of the compressor spool of a multi- shaft engine, or with the compressibility of gas in the plenum of the free power turbine of an aero-derivative unit, for example. Typical Value = 0.5.

◆ t3

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::t3

Turbine exhaust temperature time constant (T3). T3 represents delay in the exhaust temperature and load limiting system. Typical Value = 3.

◆ t4

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::t4

Governor lead time constant (T4). Typical Value = 0.

◆ t5

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::t5

Governor lag time constant (T5). Typical Value = 0.

◆ tltr

IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::tltr

Valve position averaging time constant (Tltr). Typical Value = 10.

◆ vmax

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::vmax

Maximum turbine power, PU of MWbase (Vmax). Typical Value = 1.

◆ vmin

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::TurbineGovernorDynamics::GovGAST1::vmin

Minimum turbine power, PU of MWbase (Vmin). Typical Value = 0.


The documentation for this class was generated from the following files: