Public Attributes

IEC61970::Base::Domain::CurrentFlow breakingCapacity
 
std::list< IEC61970::Base::Protection::RecloseSequence * > RecloseSequences
 
- Public Attributes inherited from IEC61970::Base::Wires::Switch
IEC61970::Base::Domain::Boolean normalOpen
 
IEC61970::Base::Domain::Boolean open
 
IEC61970::Base::Domain::CurrentFlow ratedCurrent
 
IEC61970::Base::Domain::Boolean retained
 
IEC61970::Base::Domain::Integer switchOnCount
 
IEC61970::Base::Domain::DateTime switchOnDate
 
std::list< IEC61970::Base::Wires::SwitchPhase * > SwitchPhase
 
std::list< IEC61970::Base::Wires::SwitchSchedule * > SwitchSchedules
 
- Public Attributes inherited from IEC61970::Base::Core::Equipment
IEC61970::Base::Domain::Boolean aggregate
 
IEC61970::Base::Domain::Boolean normallyInService
 
- Public Attributes inherited from IEC61970::Base::Core::PowerSystemResource
std::list< IEC61970::Base::Meas::Control * > Controls
 
std::list< IEC61970::Base::Meas::Measurement * > Measurements
 
IEC61970::Base::Core::PSRTypePSRType
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

A ProtectedSwitch is a switching device that can be operated by ProtectionEquipment.

Member Data Documentation

◆ breakingCapacity

IEC61970::Base::Domain::CurrentFlow IEC61970::Base::Wires::ProtectedSwitch::breakingCapacity

The maximum fault current a breaking device can break safely under prescribed conditions of use.

◆ RecloseSequences

std::list<IEC61970::Base::Protection::RecloseSequence*> IEC61970::Base::Wires::ProtectedSwitch::RecloseSequences

A breaker may have zero or more automatic reclosures after a trip occurs.


The documentation for this class was generated from the following files: