#include <HeatInputCurve.h>
Public Attributes | |
IEC61970::Base::Domain::PU | auxPowerMult |
IEC61970::Base::Domain::ActivePower | auxPowerOffset |
IEC61970::Base::Domain::PU | heatInputEff |
IEC61970::Base::Generation::Production::HeatRate | heatInputOffset |
IEC61970::Base::Domain::Boolean | isNetGrossP |
![]() | |
IEC61970::Base::Core::CurveStyle | curveStyle = IEC61970::Base::Core::CurveStyle::_undef |
IEC61970::Base::Domain::UnitMultiplier | xMultiplier = IEC61970::Base::Domain::UnitMultiplier::_undef |
IEC61970::Base::Domain::UnitSymbol | xUnit = IEC61970::Base::Domain::UnitSymbol::_undef |
IEC61970::Base::Domain::UnitMultiplier | y1Multiplier = IEC61970::Base::Domain::UnitMultiplier::_undef |
IEC61970::Base::Domain::UnitSymbol | y1Unit = IEC61970::Base::Domain::UnitSymbol::_undef |
IEC61970::Base::Domain::UnitMultiplier | y2Multiplier = IEC61970::Base::Domain::UnitMultiplier::_undef |
IEC61970::Base::Domain::UnitSymbol | y2Unit = IEC61970::Base::Domain::UnitSymbol::_undef |
IEC61970::Base::Domain::UnitMultiplier | y3Multiplier = IEC61970::Base::Domain::UnitMultiplier::_undef |
IEC61970::Base::Domain::UnitSymbol | y3Unit = IEC61970::Base::Domain::UnitSymbol::_undef |
std::list< IEC61970::Base::Core::CurveData * > | CurveDatas |
![]() | |
IEC61970::Base::Domain::String | aliasName |
IEC61970::Base::Domain::String | description |
IEC61970::Base::Domain::String | mRID |
IEC61970::Base::Domain::String | name |
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > | DiagramObjects |
Relationship between unit heat input in energy per time for main fuel (Y1-axis) and supplemental fuel (Y2-axis) versus unit output in active power (X-axis). The quantity of main fuel used to sustain generation at this output level is prorated for throttling between definition points. The quantity of supplemental fuel used at this output level is fixed and not prorated.
IEC61970::Base::Domain::PU IEC61970::Base::Generation::Production::HeatInputCurve::auxPowerMult |
Power output - auxiliary power multiplier adjustment factor.
IEC61970::Base::Domain::ActivePower IEC61970::Base::Generation::Production::HeatInputCurve::auxPowerOffset |
Power output - auxiliary power offset adjustment factor.
IEC61970::Base::Domain::PU IEC61970::Base::Generation::Production::HeatInputCurve::heatInputEff |
Heat input - efficiency multiplier adjustment factor.
IEC61970::Base::Generation::Production::HeatRate IEC61970::Base::Generation::Production::HeatInputCurve::heatInputOffset |
Heat input - offset adjustment factor.
IEC61970::Base::Domain::Boolean IEC61970::Base::Generation::Production::HeatInputCurve::isNetGrossP |
Flag is set to true when output is expressed in net active power.