#include <FossilSteamSupply.h>
Fossil fueled boiler (e.g., coal, oil, gas).
IEC61970::Base::Domain::PU IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::auxPowerVersusFrequency |
Off nominal frequency effect on auxiliary real power. Per unit active power variation versus per unit frequency variation.
IEC61970::Base::Domain::PU IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::auxPowerVersusVoltage |
Off nominal voltage effect on auxiliary real power. Per unit active power variation versus per unit voltage variation.
IEC61970::Base::Generation::GenerationTrainingSimulation::BoilerControlMode IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::boilerControlMode = IEC61970::Base::Generation::GenerationTrainingSimulation::BoilerControlMode::_undef |
The control mode of the boiler.
IEC61970::Base::Domain::Float IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::controlErrorBiasP |
Active power error bias ratio.
IEC61970::Base::Domain::Float IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::controlIC |
Integral constant.
IEC61970::Base::Domain::Float IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::controlPC |
Proportional constant.
IEC61970::Base::Domain::Float IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::controlPEB |
Pressure error bias ratio.
IEC61970::Base::Domain::PU IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::controlPED |
Pressure error deadband.
IEC61970::Base::Domain::Float IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::controlTC |
Time constant.
IEC61970::Base::Domain::Float IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::feedWaterIG |
Feedwater integral gain ratio.
IEC61970::Base::Domain::Float IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::feedWaterPG |
Feedwater proportional gain ratio.
IEC61970::Base::Domain::Seconds IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::feedWaterTC |
Feedwater time constant rato.
IEC61970::Base::Domain::PU IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::fuelDemandLimit |
Fuel demand limit.
IEC61970::Base::Domain::Seconds IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::fuelSupplyDelay |
Fuel delay.
IEC61970::Base::Domain::Seconds IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::fuelSupplyTC |
Fuel supply time constant.
IEC61970::Base::Domain::Float IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::maxErrorRateP |
Active power maximum error rate limit.
IEC61970::Base::Domain::Seconds IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::mechPowerSensorLag |
Mechanical power sensor lag.
IEC61970::Base::Domain::Float IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::minErrorRateP |
Active power minimum error rate limit.
IEC61970::Base::Domain::Float IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::pressureCtrlDG |
Pressure control derivative gain ratio.
IEC61970::Base::Domain::Float IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::pressureCtrlIG |
Pressure control integral gain ratio.
IEC61970::Base::Domain::Float IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::pressureCtrlPG |
Pressure control proportional gain ratio.
IEC61970::Base::Domain::Integer IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::pressureFeedback |
Pressure feedback indicator.
IEC61970::Base::Domain::Float IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::superHeater1Capacity |
Drum/primary superheater capacity.
IEC61970::Base::Domain::Float IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::superHeater2Capacity |
Secondary superheater capacity.
IEC61970::Base::Domain::Float IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::superHeaterPipePD |
Superheater pipe pressure drop constant.
IEC61970::Base::Domain::PU IEC61970::Base::Generation::GenerationTrainingSimulation::FossilSteamSupply::throttlePressureSP |
Throttle pressure setpoint.