#include <HydroPowerPlant.h>
A hydro power station which can generate or pump. When generating, the generator turbines receive water from an upper reservoir. When pumping, the pumps receive their water from a lower reservoir.
IEC61970::Base::Domain::Seconds IEC61970::Base::Generation::Production::HydroPowerPlant::dischargeTravelDelay |
Water travel delay from tailbay to next downstream hydro power station.
IEC61970::Base::Domain::ActivePower IEC61970::Base::Generation::Production::HydroPowerPlant::genRatedP |
The hydro plant's generating rating active power for rated head conditions.
IEC61970::Base::Generation::Production::Reservoir* IEC61970::Base::Generation::Production::HydroPowerPlant::GenSourcePumpDischargeReservoir |
Generators are supplied water from or pumps discharge water to an upstream reservoir.
std::list<IEC61970::Base::Generation::Production::HydroGeneratingUnit*> IEC61970::Base::Generation::Production::HydroPowerPlant::HydroGeneratingUnits |
The hydro generating unit belongs to a hydro power plant.
IEC61970::Base::Generation::Production::HydroPlantStorageKind IEC61970::Base::Generation::Production::HydroPowerPlant::hydroPlantStorageType = IEC61970::Base::Generation::Production::HydroPlantStorageKind::_undef |
The type of hydro power plant water storage.
std::list<IEC61970::Base::Generation::Production::HydroPump*> IEC61970::Base::Generation::Production::HydroPowerPlant::HydroPumps |
The hydro pump may be a member of a pumped storage plant or a pump for distributing water.
IEC61970::Base::Domain::String IEC61970::Base::Generation::Production::HydroPowerPlant::penstockType |
Type and configuration of hydro plant penstock(s).
IEC61970::Base::Domain::VolumeFlowRate IEC61970::Base::Generation::Production::HydroPowerPlant::plantDischargeCapacity |
Total plant discharge capacity.
IEC61970::Base::Domain::Length IEC61970::Base::Generation::Production::HydroPowerPlant::plantRatedHead |
The plant's rated gross head.
IEC61970::Base::Domain::ActivePower IEC61970::Base::Generation::Production::HydroPowerPlant::pumpRatedP |
The hydro plant's pumping rating active power for rated head conditions.
IEC61970::Base::Generation::Production::Reservoir* IEC61970::Base::Generation::Production::HydroPowerPlant::Reservoir |
Generators discharge water to or pumps are supplied water from a downstream reservoir.
IEC61970::Base::Domain::String IEC61970::Base::Generation::Production::HydroPowerPlant::surgeTankCode |
A code describing the type (or absence) of surge tank that is associated with the hydro power plant.
IEC61970::Base::Domain::WaterLevel IEC61970::Base::Generation::Production::HydroPowerPlant::surgeTankCrestLevel |
The level at which the surge tank spills.