#include <WindContPType4aIEC.h>
Public Attributes | |
IEC61970::Base::Domain::PU | dpmaxp4a |
IEC61970::Base::Domain::Seconds | tpordp4a |
IEC61970::Base::Domain::Seconds | tufiltp4a |
IEC61970::Dynamics::StandardModels::WindDynamics::WindTurbineType4aIEC * | WindTurbineType4aIEC |
Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject | |
IEC61970::Base::Domain::String | aliasName |
IEC61970::Base::Domain::String | description |
IEC61970::Base::Domain::String | mRID |
IEC61970::Base::Domain::String | name |
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > | DiagramObjects |
P control model Type 4A.
Reference: IEC Standard 61400-27-1 Section 5.6.5.5.
IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::WindDynamics::WindContPType4aIEC::dpmaxp4a |
Maximum wind turbine power ramp rate (dpmaxp4A). It is project dependent parameter.
IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindContPType4aIEC::tpordp4a |
Time constant in power order lag (Tpordp4A). It is type dependent parameter.
IEC61970::Base::Domain::Seconds IEC61970::Dynamics::StandardModels::WindDynamics::WindContPType4aIEC::tufiltp4a |
Voltage measurement filter time constant (Tufiltp4A). It is type dependent parameter.
IEC61970::Dynamics::StandardModels::WindDynamics::WindTurbineType4aIEC* IEC61970::Dynamics::StandardModels::WindDynamics::WindContPType4aIEC::WindTurbineType4aIEC |
Wind turbine type 4A model with which this wind control P type 4A model is associated.