IEC61970 17v23
Public Attributes | List of all members
IEC61970::Base::Protection::CurrentRelay Class Reference

#include <CurrentRelay.h>

Inheritance diagram for IEC61970::Base::Protection::CurrentRelay:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Base::Protection::CurrentRelay:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::CurrentFlow currentLimit1
 
IEC61970::Base::Domain::CurrentFlow currentLimit2
 
IEC61970::Base::Domain::CurrentFlow currentLimit3
 
IEC61970::Base::Domain::Boolean inverseTimeFlag
 
IEC61970::Base::Domain::Seconds timeDelay1
 
IEC61970::Base::Domain::Seconds timeDelay2
 
IEC61970::Base::Domain::Seconds timeDelay3
 
- Public Attributes inherited from IEC61970::Base::Protection::ProtectionEquipment
IEC61970::Base::Domain::Float highLimit
 
IEC61970::Base::Domain::Float lowLimit
 
IEC61970::Base::Domain::Boolean powerDirectionFlag
 
IEC61970::Base::Domain::Seconds relayDelayTime
 
IEC61970::Base::Domain::UnitMultiplier unitMultiplier = IEC61970::Base::Domain::UnitMultiplier::_undef
 
IEC61970::Base::Domain::UnitSymbol unitSymbol = IEC61970::Base::Domain::UnitSymbol::_undef
 
std::list< IEC61970::Base::Wires::ProtectedSwitch * > ProtectedSwitches
 
std::list< IEC61970::Base::Core::ConductingEquipment * > ConductingEquipments
 
- Public Attributes inherited from IEC61970::Base::Core::Equipment
IEC61970::Base::Domain::Boolean aggregate
 
IEC61970::Base::Domain::Boolean inService
 
IEC61970::Base::Domain::Boolean networkAnalysisEnabled
 
IEC61970::Base::Domain::Boolean normallyInService
 
- Public Attributes inherited from IEC61970::Base::Core::PowerSystemResource
std::list< IEC61970::Base::Meas::Control * > Controls
 
std::list< IEC61970::Base::Meas::Measurement * > Measurements
 
IEC61970::Base::Core::PSRTypePSRType
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

A device that checks current flow values in any direction or designated direction.

Member Data Documentation

◆ currentLimit1

IEC61970::Base::Domain::CurrentFlow IEC61970::Base::Protection::CurrentRelay::currentLimit1

Current limit number one 1 for inverse time pickup.

◆ currentLimit2

IEC61970::Base::Domain::CurrentFlow IEC61970::Base::Protection::CurrentRelay::currentLimit2

Current limit number 2 for inverse time pickup.

◆ currentLimit3

IEC61970::Base::Domain::CurrentFlow IEC61970::Base::Protection::CurrentRelay::currentLimit3

Current limit number 3 for inverse time pickup.

◆ inverseTimeFlag

IEC61970::Base::Domain::Boolean IEC61970::Base::Protection::CurrentRelay::inverseTimeFlag

Set true if the current relay has inverse time characteristic.

◆ timeDelay1

IEC61970::Base::Domain::Seconds IEC61970::Base::Protection::CurrentRelay::timeDelay1

Inverse time delay number 1 for current limit number 1.

◆ timeDelay2

IEC61970::Base::Domain::Seconds IEC61970::Base::Protection::CurrentRelay::timeDelay2

Inverse time delay number 2 for current limit number 2.

◆ timeDelay3

IEC61970::Base::Domain::Seconds IEC61970::Base::Protection::CurrentRelay::timeDelay3

Inverse time delay number 3 for current limit number 3.


The documentation for this class was generated from the following files: