IEC61970::Dynamics::StandardModels::PFVArControllerType2Dynamics::PFVArType2Common1 Class Reference

#include <PFVArType2Common1.h>

Inheritance diagram for IEC61970::Dynamics::StandardModels::PFVArControllerType2Dynamics::PFVArType2Common1:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Dynamics::StandardModels::PFVArControllerType2Dynamics::PFVArType2Common1:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::Boolean j
 
IEC61970::Base::Domain::PU ki
 
IEC61970::Base::Domain::PU kp
 
IEC61970::Base::Domain::PU max
 
IEC61970::Base::Domain::PU ref
 
- Public Attributes inherited from IEC61970::Dynamics::StandardModels::PFVArControllerType2Dynamics::PFVArControllerType2Dynamics
IEC61970::Dynamics::StandardModels::ExcitationSystemDynamics::ExcitationSystemDynamicsExcitationSystemDynamics
 
- Public Attributes inherited from IEC61970::Dynamics::StandardModels::DynamicsFunctionBlock
IEC61970::Base::Domain::Boolean enabled
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

Power factor / Reactive power regulator. This model represents the power factor or reactive power controller such as the Basler SCP-250. The controller measures power factor or reactive power (PU on generator rated power) and compares it with the operator's set point.

Member Data Documentation

◆ j

IEC61970::Base::Domain::Boolean IEC61970::Dynamics::StandardModels::PFVArControllerType2Dynamics::PFVArType2Common1::j

Selector (J). true = control mode for reactive power false = control mode for power factor.

◆ ki

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::PFVArControllerType2Dynamics::PFVArType2Common1::ki

Reset gain (Ki).

◆ kp

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::PFVArControllerType2Dynamics::PFVArType2Common1::kp

Proportional gain (Kp).

◆ max

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::PFVArControllerType2Dynamics::PFVArType2Common1::max

Output limit (max).

◆ ref

IEC61970::Base::Domain::PU IEC61970::Dynamics::StandardModels::PFVArControllerType2Dynamics::PFVArType2Common1::ref

Reference value of reactive power or power factor (Ref). The reference value is initialised by this model. This initialisation may override the value exchanged by this attribute to represent a plant operator's change of the reference setting.