IEC61970 17v07
Public Attributes | List of all members
IEC61970::Base::Wires::PhaseTapChangerAsymmetrical Class Reference

#include <PhaseTapChangerAsymmetrical.h>

Inheritance diagram for IEC61970::Base::Wires::PhaseTapChangerAsymmetrical:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Base::Wires::PhaseTapChangerAsymmetrical:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::AngleDegrees windingConnectionAngle
 
- Public Attributes inherited from IEC61970::Base::Wires::PhaseTapChangerNonLinear
IEC61970::Base::Domain::PerCent voltageStepIncrement
 
IEC61970::Base::Domain::Reactance xMax
 
IEC61970::Base::Domain::Reactance xMin
 
- Public Attributes inherited from IEC61970::Base::Wires::TapChanger
IEC61970::Base::Domain::Boolean controlEnabled
 
IEC61970::Base::Domain::Integer highStep
 
IEC61970::Base::Domain::Seconds initialDelay
 
IEC61970::Base::Domain::Integer lowStep
 
IEC61970::Base::Domain::Boolean ltcFlag
 
IEC61970::Base::Domain::Integer neutralStep
 
IEC61970::Base::Domain::Voltage neutralU
 
IEC61970::Base::Domain::Integer normalStep
 
IEC61970::Base::Domain::Float step
 
IEC61970::Base::Domain::Seconds subsequentDelay
 
IEC61970::Base::Wires::TapChangerControlTapChangerControl
 
- Public Attributes inherited from IEC61970::Base::Core::PowerSystemResource
std::list< IEC61970::Base::Meas::Control * > Controls
 
std::list< IEC61970::Base::Meas::Measurement * > Measurements
 
IEC61970::Base::Core::PSRTypePSRType
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

Describes the tap model for an asymmetrical phase shifting transformer in which the difference voltage vector adds to the primary side voltage. The angle between the primary side voltage and the difference voltage is named the winding connection angle. The phase shift depends on both the difference voltage magnitude and the winding connection angle.

Member Data Documentation

◆ windingConnectionAngle

IEC61970::Base::Domain::AngleDegrees IEC61970::Base::Wires::PhaseTapChangerAsymmetrical::windingConnectionAngle

The phase angle between the in-phase winding and the out-of -phase winding used for creating phase shift. The out-of-phase winding produces what is known as the difference voltage. Setting this angle to 90 degrees is not the same as a symmemtrical transformer.


The documentation for this class was generated from the following files: