IEC61970 17v07
Public Attributes | List of all members
IEC61970::Base::Generation::Production::HeatInputCurve Class Reference

#include <HeatInputCurve.h>

Inheritance diagram for IEC61970::Base::Generation::Production::HeatInputCurve:
Inheritance graph
[legend]
Collaboration diagram for IEC61970::Base::Generation::Production::HeatInputCurve:
Collaboration graph
[legend]

Public Attributes

IEC61970::Base::Domain::PU auxPowerMult
 
IEC61970::Base::Domain::ActivePower auxPowerOffset
 
IEC61970::Base::Domain::PU heatInputEff
 
IEC61970::Base::Generation::Production::HeatRate heatInputOffset
 
IEC61970::Base::Domain::Boolean isNetGrossP
 
- Public Attributes inherited from IEC61970::Base::Core::Curve
IEC61970::Base::Core::CurveStyle curveStyle = IEC61970::Base::Core::CurveStyle::_undef
 
IEC61970::Base::Domain::UnitMultiplier xMultiplier = IEC61970::Base::Domain::UnitMultiplier::_undef
 
IEC61970::Base::Domain::UnitSymbol xUnit = IEC61970::Base::Domain::UnitSymbol::_undef
 
IEC61970::Base::Domain::UnitMultiplier y1Multiplier = IEC61970::Base::Domain::UnitMultiplier::_undef
 
IEC61970::Base::Domain::UnitSymbol y1Unit = IEC61970::Base::Domain::UnitSymbol::_undef
 
IEC61970::Base::Domain::UnitMultiplier y2Multiplier = IEC61970::Base::Domain::UnitMultiplier::_undef
 
IEC61970::Base::Domain::UnitSymbol y2Unit = IEC61970::Base::Domain::UnitSymbol::_undef
 
IEC61970::Base::Domain::UnitMultiplier y3Multiplier = IEC61970::Base::Domain::UnitMultiplier::_undef
 
IEC61970::Base::Domain::UnitSymbol y3Unit = IEC61970::Base::Domain::UnitSymbol::_undef
 
std::list< IEC61970::Base::Core::CurveData * > CurveDatas
 
- Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject
IEC61970::Base::Domain::String aliasName
 
IEC61970::Base::Domain::String description
 
IEC61970::Base::Domain::String mRID
 
IEC61970::Base::Domain::String name
 
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > DiagramObjects
 

Detailed Description

Relationship between unit heat input in energy per time for main fuel (Y1-axis) and supplemental fuel (Y2-axis) versus unit output in active power (X-axis). The quantity of main fuel used to sustain generation at this output level is prorated for throttling between definition points. The quantity of supplemental fuel used at this output level is fixed and not prorated.

Member Data Documentation

◆ auxPowerMult

IEC61970::Base::Domain::PU IEC61970::Base::Generation::Production::HeatInputCurve::auxPowerMult

Power output - auxiliary power multiplier adjustment factor.

◆ auxPowerOffset

IEC61970::Base::Domain::ActivePower IEC61970::Base::Generation::Production::HeatInputCurve::auxPowerOffset

Power output - auxiliary power offset adjustment factor.

◆ heatInputEff

IEC61970::Base::Domain::PU IEC61970::Base::Generation::Production::HeatInputCurve::heatInputEff

Heat input - efficiency multiplier adjustment factor.

◆ heatInputOffset

IEC61970::Base::Generation::Production::HeatRate IEC61970::Base::Generation::Production::HeatInputCurve::heatInputOffset

Heat input - offset adjustment factor.

◆ isNetGrossP

IEC61970::Base::Domain::Boolean IEC61970::Base::Generation::Production::HeatInputCurve::isNetGrossP

Flag is set to true when output is expressed in net active power.


The documentation for this class was generated from the following files: