CIM++ Adapted CIM Codebase
|
#include <HydroGeneratingEfficiencyCurve.h>
Additional Inherited Members | |
Public Attributes inherited from IEC61970::Base::Core::Curve | |
IEC61970::Base::Core::CurveStyle | curveStyle |
IEC61970::Base::Domain::UnitMultiplier | xMultiplier |
IEC61970::Base::Domain::UnitSymbol | xUnit |
IEC61970::Base::Domain::UnitMultiplier | y1Multiplier |
IEC61970::Base::Domain::UnitSymbol | y1Unit |
IEC61970::Base::Domain::UnitMultiplier | y2Multiplier |
IEC61970::Base::Domain::UnitSymbol | y2Unit |
IEC61970::Base::Domain::UnitMultiplier | y3Multiplier |
IEC61970::Base::Domain::UnitSymbol | y3Unit |
std::list< IEC61970::Base::Core::CurveData * > | CurveDatas |
Public Attributes inherited from IEC61970::Base::Core::IdentifiedObject | |
IEC61970::Base::Domain::String | aliasName |
IEC61970::Base::Domain::String | description |
IEC61970::Base::Domain::String | mRID |
IEC61970::Base::Domain::String | name |
std::list< IEC61970::Base::DiagramLayout::DiagramObject * > | DiagramObjects |
Relationship between unit efficiency in percent and unit output active power for a given net head in meters. The relationship between efficiency, discharge, head, and power output is expressed as follows: E =KP/HQ Where: (E=percentage) (P=active power) (H=height) (Q=volume/time unit) (K=constant) For example, a curve instance for a given net head could relate efficiency (Y- axis) versus active power output (X-axis) or versus discharge on the X-axis.